International heart journal · 2021
Early Vascular Response to Ultrathin Biodegradable Polymer Sirolimus-Eluting Stents for the Treatment of ST-Elevation Myocardial Infarction After Plaque Rupture.
СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Oishi Yosuke, Tsujita Hiroaki, Ogura Kunihiro, Matsukawa Naoki, Tanaka Hideaki, Masaki Ryota, Sakai Koshiro, Sekimoto Teruo, Kondo Seita, Tsukamoto Shigeto, Matsumoto Hidenari, Mori Hiroyoshi, Arai Ken, Nomura Kosuke, Sato Syunya, Yamamoto Myong Hwa, Kosaki Ryota, Wakabayashi Kohei, Sakai Rikuo, Arai Taito, Suzuki Hiroshi, Ochiai Masahiko, Shinke Toshiro
Аннотация
Recent clinical studies suggest that newer-generation drug-eluting stents that combine ultrathin struts and nanocoating (biodegradable polymer sirolimus-eluting stents, BP-SES) could improve long-term clinical outcomes in patients with ST-elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI). However, the early vascular response to BP-SES in these patients has not been investigated so far.We examined this response in 20 patients with STEMI caused by plaque rupture using frequency-domain optical coherence tomography (OCT) to understand the underlying mechanisms. Plaque rupture was diagnosed by OCT before PCI with BP-SES implantation was performed. OCT was again performed before the final angiography (post-PCI) and after 2 weeks (2W-OCT).BP-SES placement caused protrusion of atherothrombotic material into the stent lumen and incomplete stent apposition in all patients. After 2 weeks, incomplete stent apposition was significantly reduced (% malapposed struts: post-PCI 4.7 ± 3.3%; 2W-OCT 0.9 ± 1.2%; P < 0.0001), and the percentage of uncovered struts also significantly decreased (% uncovered struts: post-PCI; 69.8 ± 18.3%: 2W-OCT; 29.6 ± 11.0%, P < 0.0001). The maximum protrusion area of the atherothrombotic burden was significantly reduced (post-PCI 1.36 ± 0.70 mm2; 2W-OCT 0.98 ± 0.55 mm2; P = 0.004).This study on the early vascular responses following BP-SES implantation showed rapid resolution of atherothrombotic material and progression of strut apposition and coverage. (UMIN000041324).