MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.29470

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2021

Right transradial coronary angiography in the setting of tortuous brachiocephalic/thoracic aorta ("elephant head"): Impact on fluoroscopy time and contrast use.

Case Brian C, Yerasi Charan, Forrestal Brian J, Chezar-Azerrad Chava, Khan Jaffar M, Khalid Nauman, Shlofmitz Evan, Chen Yuefeng, Musallam Anees, Waksman Ron, Hashim Hayder

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Assess the impact on fluoroscopy time and contrast use in patients with tortuous brachiocephalic/thoracic aortas undergoing right transradial coronary angiography (RTCA) and provide strategies to manage.

BACKGROUND

Unfavorable anatomy with severe brachiocephalic/thoracic tortuosity, referred to as an "elephant head," remains a significant obstacle for RTCA.

METHODS

We reviewed the coronary angiograms of patients who underwent RTCA and had tortuous aortas. Angiography was attempted first using a universal catheter (Tiger) and switched to a left coronary specific catheter (Judkins Left [JL]) if challenging. Fluoroscopy time, contrast volume, and greatest distance from the patient's midline to the catheter in the aorta were recorded.

RESULTS

Forty-nine patients (62.6 ± 12.0 years, 69.4% male) were included. Fifteen (30.6%) patients underwent successful angiography with a Tiger catheter; 34 (69.4%) patients required switching to JL catheter. The average distance of Tiger catheters to the midline of the spine was 0.78 ± 0.41 cm versus 1.28 ± 0.44 cm (p = .001) in JL catheters. Tiger catheter use resulted in less fluoroscopy time (6.48 ± 4.73 min) and contrast use (58.87 ± 43.53 ml) than in cases switched to JL (13.26 ± 10.76 min [p = .026]; 86.5 ± 69.95 ml [(p = .017]).

CONCLUSIONS

For patients undergoing RTCA with significant brachiocephalic/thoracic aorta tortuosity, "elephant head," a Tiger catheter can be used efficiently for curvatures <1 cm from the middle of the spine. We propose that for curvatures >1 cm, operators should consider immediately switching to a JL catheter.

Для цитирования: Case Brian C, Yerasi Charan, Forrestal Brian J, Chezar-Azerrad Chava, Khan Jaffar M, Khalid Nauman, Shlofmitz Evan, Chen Yuefeng, Musallam Anees, Waksman Ron, Hashim Hayder. Right transradial coronary angiography in the setting of tortuous brachiocephalic/thoracic aorta ("elephant head"): Impact on fluoroscopy time and contrast use.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2021. DOI: 10.1002/ccd.29470.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.