Biomedical physics & engineering express · 2020
Patient-specific 3D-printed coronary models based on coronary computed tomography angiography volumes to investigate flow conditions in coronary artery disease.
СтатьяПоддержка NIH: внешняя программаНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sommer Kelsey N, Shepard Lauren M, Mitsouras Dimitrios, Iyer Vijay, Angel Erin, Wilson Michael F, Rybicki Frank J, Kumamaru Kanako Kunishima, Sharma Umesh C, Reddy Abhinay, Fujimoto Shinichiro, Ionita Ciprian N
Аннотация
BACKGROUND: 3D printed patient-specific coronary models have the ability to enable repeatable benchtop experiments under controlled blood flow conditions. This approach can be applied to CT-derived patient geometries to emulate coronary flow and related parameters such as Fractional Flow Reserve (FFR).
METHODS: This study uses 3D printing to compare such benchtop FFR results with a non-invasive CT-FFR research software algorithm and catheter based invasive FFR (I-FFR) measurements. Fifty-two patients with a clinical indication for I-FFR underwent a research Coronary CT Angiography (CCTA) prior to catheterization. CT images were used to measure CT-FFR and to generate patient-specific 3D printed models of the aortic root and three main coronary arteries. Each patient-specific model was connected to a programmable pulsatile pump and benchtop FFR (B-FFR) was derived from pressures measured proximal and distal to coronary stenosis using pressure transducers. B-FFR was measured for two coronary outflow rates ('normal', 250 ml min-1; and 'hyperemic', 500 ml min-1) by adjusting the model's distal coronary resistance.
RESULTS: Pearson correlations and ROC AUC were calculated using invasive I-FFR as reference. The Pearson correlation factor of CT-FFR and B-FFR-500 was 0.75 and 0.71, respectively. Areas under the ROCs for CT-FFR and B-FFR-500 were 0.80 (95%CI: 0.70-0.87) and 0.81 (95%CI: 0.64-0.91) respectively.
CONCLUSION: Benchtop flow simulations with 3D printed models provide the capability to measure pressure changes at any location in the model, for ultimately emulating the FFR at several simulated physiological blood flow conditions.
CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/show/NCT03149042.
METHODS: This study uses 3D printing to compare such benchtop FFR results with a non-invasive CT-FFR research software algorithm and catheter based invasive FFR (I-FFR) measurements. Fifty-two patients with a clinical indication for I-FFR underwent a research Coronary CT Angiography (CCTA) prior to catheterization. CT images were used to measure CT-FFR and to generate patient-specific 3D printed models of the aortic root and three main coronary arteries. Each patient-specific model was connected to a programmable pulsatile pump and benchtop FFR (B-FFR) was derived from pressures measured proximal and distal to coronary stenosis using pressure transducers. B-FFR was measured for two coronary outflow rates ('normal', 250 ml min-1; and 'hyperemic', 500 ml min-1) by adjusting the model's distal coronary resistance.
RESULTS: Pearson correlations and ROC AUC were calculated using invasive I-FFR as reference. The Pearson correlation factor of CT-FFR and B-FFR-500 was 0.75 and 0.71, respectively. Areas under the ROCs for CT-FFR and B-FFR-500 were 0.80 (95%CI: 0.70-0.87) and 0.81 (95%CI: 0.64-0.91) respectively.
CONCLUSION: Benchtop flow simulations with 3D printed models provide the capability to measure pressure changes at any location in the model, for ultimately emulating the FFR at several simulated physiological blood flow conditions.
CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/show/NCT03149042.
Предметные рубрики MeSH
AgedAlgorithmsCardiac CatheterizationComputed Tomography AngiographyCoronary AngiographyCoronary Artery DiseaseCoronary StenosisCoronary VesselsFemaleFractional Flow Reserve, MyocardialHemodynamicsHumansImaging, Three-DimensionalMaleMiddle AgedMultidetector Computed TomographyProspective StudiesROC CurveSoftwareTomography, X-Ray Computed