m+Medelevator.RU
← Поиск публикаций
Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2023

Use of immobilisation bra for daily setup of patients with pendulous breasts undergoing radiotherapy.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chua J Z, Lim L H, Pang E P P, Kusumawidjaja G

Аннотация

PURPOSE: A feasibility study to evaluate the Chabner XRT® Radiation Bra (CIVCO Radiotherapy & Qfix, Coralville, IA, USA) as a customised immobilisation device for patients with pendulous breasts undergoing radiotherapy was conducted.

METHODS: A total of 34 patients with large pendulous breasts were fitted with the Chabner XRT® Radiation Bra during RT. A mixed-method questionnaire was administered to both radiation therapists (RTTs) and patients. RTTs evaluated the effectiveness of the bra in setup. Patients appraised its comfort level and ease of wearing. Setup reproducibility was evaluated based on a departmental imaging protocol. Acute skin side effects were documented with photos and assessed using the Radiation Therapy Oncology Group (RTOG) classification.

RESULTS: Of the patients, 27 (79.4%) completed the questionnaire. 23 patients felt comfortable wearing the bra while 20 felt less exposed during treatment. Reproducibility was acceptable, with a median (range) setup error (isocentre) of 0.0 cm (-0.6 to 0.7 cm; left/right), -0.1 cm (-0.5 to 1.2 cm; posterior) and 0.2 cm (-0.5 to 0.9 cm; inferior) achieved based on matched field borders on skin. However, repeated setups and imaging were required for 3 patients due to large breast size (cups D-G; size 4-5). Minimal skin toxicity (grade 0-1) was observed. No grade ≥ 2 was reported. 10 RTTs completed the survey. Male RTTs (n = 4) were not confident in assisting patients with bra fitting. 8 RTTs agreed that although it was difficult to reproduce the breast tissue for treatment, it helped patients to maintain the treatment position.

CONCLUSION: Our study demonstrated the feasibility of using a customised bra which provided optimal setup reproducibility while maintaining minimal skin toxicity and patient comfort, especially the value-added modesty felt among Asian women during their breast cancer radiotherapy.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты