MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.radonc.2023.109872

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2023

Carbon-ion radiotherapy (CIRT) as treatment of pancreatic cancer at HIT: initial radiation plan analysis of the prospective phase II PACK-study.

Baltazar Filipa, Tessonnier Thomas, Haberer Thomas, Debus Juergen, Herfarth Klaus, Tawk Bouchra, Knoll Maximilian, Abdollahi Amir, Liermann Jakob, Mairani Andrea

СтатьяКлиническое исследование II фазыПеревод пока не подготовлен

Аннотация

PURPOSE: To analyze the dose objectives and constraints applied at the prospective phase II PACK-study at Heidelberg ion therapy center (HIT) for different radiobiological models.

METHODS

Treatment plans of 14 patients from the PACK-study were analyzed and recomputed in terms of physical, biological dose and dose-averaged linear energy transfer (LETd). Both LEM-I (local effect model 1) and the adapted NIRS-MKM (microdosimetric kinetic model), were used for relative biological effectiveness (RBE)-weighted dose calculations (DBio|HIT and DBio|NIRS). A new constraint to the gastrointestinal (GI) tract was derived from the National Institute of Radiological Science (NIRS) clinical experience and considered for plan reoptimization (DBio|NIRS-const_48Gy and DBio|NIRS-const_50.4Gy). The Lyman-Kutcher-Burman (LKB) model of Normal Tissue Complication Probability (NTCP) for GI toxicity endpoints was computed. Furthermore, the computed LETd distribution was evaluated and correlated with Local Control (LC).

RESULTS

Only two patients showed a LETd98% in the GTV greater than 44 keV/μm. A HIT-dose constraint to the GI of [Formula: see text] was derived from the NIRS experience, in alternative to the standard at HIT Dmax = 45.6 GyRBEHIT. In comparison with the original DBio|HIT,DBio|NIRS-const_48GyandDBio|NIRS-const_50.4Gy resulted in an increase in the ITV's D98% of 8.7% and 11.3%. The NTCP calculation resulted in a probability for gastrointestinal bleeding of 4.5%, 12.3% and 13.0%, for DBio|NIRS, DBio|NIRS-const_48Gy and DBio|NIRS-const_50.4Gy, respectively.

CONCLUSION

The results indicate that the current standards applied at HIT for CIRT closely align with the Japanese experience. However, to enhance tumor coverage, a more relaxed constraint on the GI tract may be considered. As the PACK-trial progresses, further analyses of various clinical endpoints are anticipated.

Для цитирования: Baltazar Filipa, Tessonnier Thomas, Haberer Thomas, Debus Juergen, Herfarth Klaus, Tawk Bouchra, Knoll Maximilian, Abdollahi Amir, Liermann Jakob, Mairani Andrea. Carbon-ion radiotherapy (CIRT) as treatment of pancreatic cancer at HIT: initial radiation plan analysis of the prospective phase II PACK-study.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2023. DOI: 10.1016/j.radonc.2023.109872.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.