Clinica chimica acta; international journal of clinical chemistry · 2019
Determination of serum imatinib and its' metabolite in patients chronic myeloid leukemia.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Onmaz Duygu Eryavuz, Abusoglu Sedat, Unlu Ali, Basturk Abdulkadir, Dagli Mehmet, Bagci Metin, Tok Oguzhan, Abusoglu Gulsum
Аннотация
INTRODUCTION: Imatinib has favorable pharmacokinetic properties, but primary and secondary resistance mechanisms may cause a decrease in clinical response over time. There is a positive correlation between serum imatinib concentrations and treatment response. Our aim was to develop a method for the measurement of imatinib and its' active metabolite N-desmethyl imatinib.
METHODS: Serum imatinib and N-desmethyl imatinib levels were determined by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and validation studies were carried out according to CLSI (The Clinical & Laboratory Standards Institute) protocols. Serum samples were collected from 40 patients with chronic myeloid leukemia (CML) and analyzed with LC-MS/MS and ultra high-performance liquid chromatography (UHPLC) methods.
RESULTS: The linearity range and correlation coefficient were 12.2-12,500 ng/mL and 0.9987 for LC-MS/MS method, respectively. Limit of quantitation was determined as 24.4 ng/mL. The retention times of imatinib and N-desmethyl imatinib were 1.66 and 1.60 min, respectively. There was no statistically significant difference between the results of both methods.
DISCUSSION: This LC-MS/MS method is cost-effective and has adavantages such as using low serum volumes, requiring simple pretreatment steps (only protein precipitation) and reduced turnaround times for analysis.
METHODS: Serum imatinib and N-desmethyl imatinib levels were determined by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and validation studies were carried out according to CLSI (The Clinical & Laboratory Standards Institute) protocols. Serum samples were collected from 40 patients with chronic myeloid leukemia (CML) and analyzed with LC-MS/MS and ultra high-performance liquid chromatography (UHPLC) methods.
RESULTS: The linearity range and correlation coefficient were 12.2-12,500 ng/mL and 0.9987 for LC-MS/MS method, respectively. Limit of quantitation was determined as 24.4 ng/mL. The retention times of imatinib and N-desmethyl imatinib were 1.66 and 1.60 min, respectively. There was no statistically significant difference between the results of both methods.
DISCUSSION: This LC-MS/MS method is cost-effective and has adavantages such as using low serum volumes, requiring simple pretreatment steps (only protein precipitation) and reduced turnaround times for analysis.