MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The Journal of urology · 1996

The Glidewire technique for overcoming urethral obstruction.

Freid R M, Smith A D

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Using the hydrophilic Terumo Glidewire we developed a less traumatic, yet effective alternative method to filiforms and followers for cases of urethral obstruction.

MATERIALS AND

METHODS

The initial step and cornerstone of our method is the passage of the Glidewire per urethra in a manner similar to a filiform. After the appropriate intravesical location of the Glidewire is confirmed using a ureteral catheter, it is exchanged for a standard polytetrafluoroethylene (Teflon) coated guide wire. Urethral dilation and/or catheter placement is then performed.

RESULTS

This technique was successful in 19 of 20 attempts, several of which followed unsuccessful passage of filliform catheters. Urethral obstruction due to strictures, bladder neck contractures and benign prostatic hyperplasia in our group was treated effectively. Furthermore, no complications occurred due to the technique.

CONCLUSIONS

The Glidewire method is safe and effective for treating most cases of urethral obstruction. Therefore, we recommend this technique over standard filiforms and followers when flexible or rigid cystourethroscopy is not immediately available.

Для цитирования: Freid R M, Smith A D. The Glidewire technique for overcoming urethral obstruction.. The Journal of urology. 1996.