Exoscope-Assisted Stapedotomy: Evaluation of Safety and Efficacy.

Conway Robert M, Fan Caleb J, Choi Jonathan S, Babu Kavan, Mallany Hugh P, Babu Seilesh C

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Evaluate the safety and efficacy of exoscope-assisted stapedotomy.

STUDY

DESIGN

Retrospective chart review.

SETTING

Tertiary care neurotology clinic.

PATIENTS: Adult patients with otosclerosis undergoing stapedotomy.

INTERVENTIONS: Primary stapedotomy.

MAIN OUTCOME MEASURES: Evaluation of audiologic outcomes, including pure-tone average, bone-conduction thresholds, word recognition score, and air-bone gap. Complications, need for scutum removal, and length of surgery were also evaluated.

RESULTS

A total of 47 patients were identified, and 24 patients underwent surgery with the microscope and 22 with the exoscope. There were significant improvements in pure-tone average, mean bone-conduction thresholds, and air-bone gap for both groups. There was no difference in preoperative or postoperative audiologic status for either group. There was no difference in rates of dysgeusia, chorda tympani nerve damage, dizziness, or facial paresis in either group.

CONCLUSIONS

This study indicates similar audiologic outcomes, complication profiles, and visualization when comparing exoscopic and microscopic stapedotomy. Demonstrated here, exoscopic stapedotomy can be safely performed in a transcanal manner.

Для цитирования: Conway Robert M, Fan Caleb J, Choi Jonathan S, Babu Kavan, Mallany Hugh P, Babu Seilesh C. Exoscope-Assisted Stapedotomy: Evaluation of Safety and Efficacy.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2023. DOI: 10.1097/mao.0000000000004042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.