MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0034-1366057

Медицинская библиотека · Ultraschall in der Medizin (Stuttgart, Germany : 1980) · 2014

Liver stiffness assessed by acoustic radiation force impulse (ARFI) technology is considerably increased in patients with cholestasis.

Pfeifer L, Strobel D, Neurath M F, Wildner D

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To explore the impact of cholestasis on liver stiffness assessed by acoustic radiation force impulse (ARFI) technology.

MATERIALS AND

METHODS

Over a period of four months, patients with sonographic cholestasis and increased cholestatic blood values (Bilirubin, γGT, AP > 2 times ULN) scheduled for endoscopic therapy were recruited. Exclusion criteria were: known liver disease; signs of cirrhosis at ultrasound (irregular liver veins and/or surface); heart insufficiency (NYHA III-VI). ARFI (Siemens S2000), ultrasound and blood examinations were performed before and in a subgroup after successful biliary drainage.

RESULTS

In total, 21 patients with cholestasis were included in the study. ARFI measurements were above the cut-off for cirrhosis (1.8  m/s) in all patients with a mean of 2.91  m/s ± 0.89  m/s without a history or signs of cirrhosis. Bilirubin, γGT and AP were elevated on average to 9.7 ± 5.3  mg/dl, 1192 ± 960  U/l and 730 ± 389  U/l. A subgroup of 10 patients was measured after successful drainage. ARFI measurements declined in all patients of that subgroup on average by 0.76  m/s at a mean time interval of 4.5 days (p < 0.001).

CONCLUSION

Cholestasis significantly increases liver stiffness assessed by ARFI. Therefore, it is important to exclude profound cholestasis when using ARFI for evaluating patients for liver fibrosis.

Для цитирования: Pfeifer L, Strobel D, Neurath M F, Wildner D. Liver stiffness assessed by acoustic radiation force impulse (ARFI) technology is considerably increased in patients with cholestasis.. Ultraschall in der Medizin (Stuttgart, Germany : 1980). 2014. DOI: 10.1055/s-0034-1366057.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.