MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ygyno.2008.03.005

Медицинская библиотека · Gynecologic oncology · 2008

A randomized phase III trial of VH fibrin sealant to reduce lymphedema after inguinal lymph node dissection: a Gynecologic Oncology Group study.

Carlson Jay W, Kauderer James, Walker Joan L, Gold Michael A, O'Malley David, Tuller Erin, Clarke-Pearson Daniel L, Gynecologic Oncology Group

Клиническое исследование III фазыСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate VH fibrin sealant's influence on lower extremity lymphedema after inguinal lymphadenectomy in vulvar cancer patients.

METHODS

Patients undergoing an inguinal lymphadenectomy during the management of vulvar malignancy were randomized to receive sutured closure (SC) vs VH fibrin sealant sprayed into the groin followed by sutured closure (FS). Leg measurements were taken preoperatively and during postoperative encounters when surgical outcomes were assessed. Grade 2 or 3 lymphedema was defined as circumferential measurement increases of 3-5 cm and >5 cm, respectively.

RESULTS

150 patients were enrolled. 137 patients were evaluable for lymphedema analysis with 67 and 70 patients in the SC arm and FS arm, respectively. The incidence of grade 2 and 3 lymphedema was 67%(45/67) in the SC arm, and 60% (42/70) FS arm (p=0.4779). The incidence of lymphedema was strongly associated with inguinal infection (p=0.0165). Lymphedema was not statistically increased in those who received adjuvant radiation. 139 patients remained evaluable for a descriptive analysis of their surgical complications. The overall incidence of complications was 61%(43/70) and 59% (41/69) for SC and FS arms, respectively. There was no statistically significant difference in duration of drains, drain output or incidence of inguinal infections, wound breakdowns or seromas. There was an increased incidence of vulvar infections in the FS arm (23/69) vs (10/70) (p=0.0098). The utilization of a Blake drain was associated with an increase in vulvar (p=0.0157) and inguinal wound breakdown (p=0.0456).

CONCLUSION

VH fibrin sealant in inguinal lymphadenectomies does not reduce leg lymphedema and may increase the risk for complications in the vulvar wound.

Для цитирования: Carlson Jay W, Kauderer James, Walker Joan L, Gold Michael A, O'Malley David, Tuller Erin, Clarke-Pearson Daniel L, Gynecologic Oncology Group. A randomized phase III trial of VH fibrin sealant to reduce lymphedema after inguinal lymph node dissection: a Gynecologic Oncology Group study.. Gynecologic oncology. 2008. DOI: 10.1016/j.ygyno.2008.03.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.