[Atrio-oesophageal fistula after thoracoscopic treatment of atrial fibrillation].
Аннотация
BACKGROUND
An atrio-oesophageal fistula (AOF) is a rare but severe complication of radiofrequency ablation during video-assisted thoracoscopic pulmonary vein isolation (VATS-PVI).
CASE DESCRIPTION: A 68-year-old man presented to the emergency department with reduced general well-being and a fever. Eight weeks prior he had undergone a VATS-PVI. Blood results revealed elevated inflammatory parameters, and blood cultures were positive for Streptococcus anginosus. A CT-scan demonstrated an air configuration in the left atrium. Shortly after this he developed a left-sided hemiparesis. As a cerebral air embolus due to an AOF was suspected, we decided to operate. The defects in the atrium and the oesophagus were closed primarily during open-heart surgery.
CONCLUSION
An AOF is a rare complication following a VATS-PVI. Patients often present with non-specific symptoms like a fever. It is important to be alert of this complication after a VATS-PVI and to perform early diagnostic imaging.