Le Feuvre Claude, Batisse Anne, Collet Jean P, Batisse Jean P, Choussat Rémy, Beygui Farzin, Helft Gérard, Montalescot Gilles, Metzger Jean P
Аннотация
OBJECTIVES: Our study aimed to compare the isosmolar nonionic dimer iodixanol and the low osmolar ionic agent ioxaglate in the current era of percutaneous coronary intervention (PCI), using clopidogrel, enoxaparine, direct stenting, and drug eluting stent.
BACKGROUND: Previous studies have suggested an association between thrombus-related events and type of contrast media.
METHODS: Our prospective single-center study included 498 consecutive patients who were assigned to receive either iodixanol (n = 231) or ioxaglate (n = 267). The primary endpoint was the cumulative rate of in-hospital major adverse clinical events (MACE). A secondary endpoint was the rate of angiographic or procedural complications.
RESULTS: Clinical and angiographic baseline characteristics and procedural data were similar in the 2 groups. A peak anti-Xa > 0.5 IU/ml was obtained in 97% in both groups. Glycoprotein IIb/IIIa inhibitors were used in 42% of patients. Coronary stenting was performed in 91% of patients, with direct stenting in 70%, and drug-eluting stent in 28% of patients. In-hospital MACE was more frequent in patients receiving iodixanol compared with those receiving ioxaglate (4.8% vs. 0.3%, P < 0.005). This difference was mainly related to the appearance of a large thrombus during PCI (6% with iodixanol vs. 0.3% with ioxaglate, P < 0.0001). In multivariate analysis, independent predictors of in-hospital MACE were use of iodixanol (P < 0.01), the higher number of stent used (P < 0.008), bifurcation/ostial lesion (P < 0.01), and balloon dilation before stenting (p < 0.001).
CONCLUSIONS: In our study reflecting the current era of PCI, thrombus-related events are more frequent with the isosmolar nonionic dimer iodixanol than with the low osmolar ionic agent ioxaglate.
BACKGROUND: Previous studies have suggested an association between thrombus-related events and type of contrast media.
METHODS: Our prospective single-center study included 498 consecutive patients who were assigned to receive either iodixanol (n = 231) or ioxaglate (n = 267). The primary endpoint was the cumulative rate of in-hospital major adverse clinical events (MACE). A secondary endpoint was the rate of angiographic or procedural complications.
RESULTS: Clinical and angiographic baseline characteristics and procedural data were similar in the 2 groups. A peak anti-Xa > 0.5 IU/ml was obtained in 97% in both groups. Glycoprotein IIb/IIIa inhibitors were used in 42% of patients. Coronary stenting was performed in 91% of patients, with direct stenting in 70%, and drug-eluting stent in 28% of patients. In-hospital MACE was more frequent in patients receiving iodixanol compared with those receiving ioxaglate (4.8% vs. 0.3%, P < 0.005). This difference was mainly related to the appearance of a large thrombus during PCI (6% with iodixanol vs. 0.3% with ioxaglate, P < 0.0001). In multivariate analysis, independent predictors of in-hospital MACE were use of iodixanol (P < 0.01), the higher number of stent used (P < 0.008), bifurcation/ostial lesion (P < 0.01), and balloon dilation before stenting (p < 0.001).
CONCLUSIONS: In our study reflecting the current era of PCI, thrombus-related events are more frequent with the isosmolar nonionic dimer iodixanol than with the low osmolar ionic agent ioxaglate.
Предметные рубрики MeSH
Angioplasty, Balloon, CoronaryCardiovascular DiseasesClopidogrelContrast MediaCoronary AngiographyDrug Delivery SystemsEnoxaparinFemaleHumansIncidenceIoxaglic AcidMaleMiddle AgedOsmolar ConcentrationPlatelet Aggregation InhibitorsPostoperative ComplicationsProspective StudiesRisk FactorsStentsThrombosisTiclopidineTriiodobenzoic Acids