Surgical endoscopy · 2020
Da Vinci Single-Port robot-assisted transanal mesorectal excision: a promising preclinical experience.
Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kneist Werner, Stein Hubert, Rheinwald Markus
Аннотация
INTRODUCTION: Robotic single-port platforms represent a viable option for advanced surgical procedures. This preclinical study investigated the dual-field, single-port, robot-assisted transanal total mesorectal excision (taTME).
TECHNIQUE: In a male human cadaver, we employed the novel da Vinci® SP™ Surgical System, sequentially, to realize the transanal and abdominal parts of the taTME procedure. We evaluated the feasibility of the one-team approach.
RESULTS: We showed that single-port access for the taTME was technically feasible with the current da Vinci® SP™ Surgical System in both surgical fields. The total console times were 189 min for the juxta-anal purse-string suture placement, partial intersphincteric resection, and bottom-up mesorectal dissection to where it meets the peritoneal reflection and 43 min for the abdominal procedure. A good quality specimen was achieved. The surgeon comfort was high during simulated surgery. The task load was highly acceptable (NASA-TLX global score: 35), even though it was the surgeon's first use of this platform.
CONCLUSION: This preclinical study demonstrated that the robotic, single-port taTME was feasible and could be performed with the da Vinci® SP™ Surgical System, beginning at the level of the dentate line. Further simulations are necessary to confirm this promising approach.
TECHNIQUE: In a male human cadaver, we employed the novel da Vinci® SP™ Surgical System, sequentially, to realize the transanal and abdominal parts of the taTME procedure. We evaluated the feasibility of the one-team approach.
RESULTS: We showed that single-port access for the taTME was technically feasible with the current da Vinci® SP™ Surgical System in both surgical fields. The total console times were 189 min for the juxta-anal purse-string suture placement, partial intersphincteric resection, and bottom-up mesorectal dissection to where it meets the peritoneal reflection and 43 min for the abdominal procedure. A good quality specimen was achieved. The surgeon comfort was high during simulated surgery. The task load was highly acceptable (NASA-TLX global score: 35), even though it was the surgeon's first use of this platform.
CONCLUSION: This preclinical study demonstrated that the robotic, single-port taTME was feasible and could be performed with the da Vinci® SP™ Surgical System, beginning at the level of the dentate line. Further simulations are necessary to confirm this promising approach.