van Rooijen Mathilde Mj, Jairam An P, Tollens Tim, Jørgensen Lars N, de Vries Reilingh Tammo S, Piessen Guillaume, Köckerling Ferdinand, Miserez Marc, Windsor Alastair Cj, Berrevoet Frederik, Fortelny René H, Dousset Bertrand, Woeste Guido, van Westreenen Henderik L, Gossetti Francesco, Lange Johan F, Tetteroo Geert Wm, Koch Andreas, Kroese Leonard F, Jeekel Johannes

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Resorbable biomaterials have been developed to reduce the amount of foreign material remaining in the body after hernia repair over the long-term. However, on the short-term, these resorbable materials should render acceptable results with regard to complications, infections, and reoperations to be considered for repair. Additionally, the rate of resorption should not be any faster than collagen deposition and maturation; leading to early hernia recurrence. Therefore, the objective of this study was to collect data on the short-term performance of a new resorbable biosynthetic mesh (Phasix™) in patients requiring Ventral Hernia Working Group (VHWG) Grade 3 midline incisional hernia repair.

MATERIALS AND

METHODS

A prospective, multi-center, single-arm trial was conducted at surgical departments in 15 hospitals across Europe. Patients aged ≥18, scheduled to undergo elective Ventral Hernia Working Group Grade 3 hernia repair of a hernia larger than 10 cm2 were included. Hernia repair was performed with Phasix™ Mesh in sublay position when achievable. The primary outcome was the rate of surgical site occurrence (SSO), including infections, that required intervention until 3 months after repair.

RESULTS

In total, 84 patients were treated with Phasix™ Mesh. Twenty-two patients (26.2%) developed 32 surgical site occurrences. These included 11 surgical site infections, 9 wound dehiscences, 7 seromas, 2 hematomas, 2 skin necroses, and 1 fistula. No significant differences in surgical site occurrence development were found between groups repaired with or without component separation technique, and between clean-contaminated or contaminated wound sites. At three months, there were no hernia recurrences.

CONCLUSION

Phasix™ Mesh demonstrated acceptable postoperative surgical site occurrence rates in patients with a Ventral Hernia Working Group Grade 3 hernia. Longer follow-up is needed to evaluate the recurrence rate and the effects on quality of life. This study is ongoing through 24 months of follow-up.

Для цитирования: van Rooijen Mathilde Mj, Jairam An P, Tollens Tim, Jørgensen Lars N, de Vries Reilingh Tammo S, Piessen Guillaume, Köckerling Ferdinand, Miserez Marc, Windsor Alastair Cj, Berrevoet Frederik, Fortelny René H, Dousset Bertrand, Woeste Guido, van Westreenen Henderik L, Gossetti Francesco, Lange Johan F, Tetteroo Geert Wm, Koch Andreas, Kroese Leonard F, Jeekel Johannes. Outcomes of a new slowly resorbable biosynthetic mesh (Phasix™) in potentially contaminated incisional hernias: A prospective, multi-center, single-arm trial.. International journal of surgery (London, England). 2020. DOI: 10.1016/j.ijsu.2020.08.053.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.