DOI 10.1515/cclm-2026-0579

Медицинская библиотека · Clinical chemistry and laboratory medicine · 2026

New insights in primary aldosteronism diagnosis: a prospective multicenter study.

Wang Kaijuan, Ma Wenjun, Cong Hongying, Gao Xiaojing, Zhang Wei, Gao Zhangwei, Yang Shumin, Zhao Yajing, Chen Rong, Lin Ya, Cheng Wenli, Yuan Hui, Hao Sufang, Zhou Houqing, Zhao Qiuping, Xu Poshi, Wu Wei, Zhang Zhenlu, Zhou Weiyan, Li Qifu, Cai Jun, Zhou Zhou

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVES

The high variability in screening and confirmatory cut-off values for primary aldosteronism (PA) largely reflects the insufficient standardization of current analytical methods. Competitive and sandwich immunoassays show variable correlation with the reference liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique. This prospective multicenter study aimed to establish diagnostic thresholds for PA using a novel sandwich immunoassay.

METHODS

A total of 676 patients suspected of PA were consecutively enrolled from 7 medical centers in China. All participants underwent a captopril challenge test (CCT), followed by a seated saline infusion test (sSIT) on the third day. Plasma aldosterone concentration (PAC) and plasma renin concentration (PRC) were measured using a fully automated chemiluminescent immunoassay platform (Maglumi X8, SNIBE, China). PA was diagnosed according to current clinical guidelines.

RESULTS

An aldosterone renin ratio (ARR) cut-off of 11 ng/L/mU/L showed 90 % sensitivity (95 % CI: 85-94 %) and 62 % specificity (95 % CI: 58-67 %) with the area under the receiver-operator characteristic curves (AUC) of 0.843 (95 % CI: 0.81-0.87). PAC post-sSIT and PAC post-CCT exhibited comparable diagnostic performance (AUC 0.818, 95 % CI: 0.79-0.85 vs. AUC 0.848, 95 % CI: 0.82-0.88; p=0.1388). Using cut-off of 56 ng/L and 59 ng/L for post-SIT and post-CCT yielded a specificity of 85 % (95 % CI: 81-88 %). Notably, to achieve a higher specificity of 90 %, the corresponding PAC cut-off values increased to 64 ng/L post-SIT and 66 ng/L post-CCT.

CONCLUSIONS

Adjustment of current cut-off values for the screening and confirmation of PA is necessary when a more accurate chemiluminescent sandwich immunoassay is used for measuring PAC and PRC.

Для цитирования: Wang Kaijuan, Ma Wenjun, Cong Hongying, Gao Xiaojing, Zhang Wei, Gao Zhangwei, Yang Shumin, Zhao Yajing, Chen Rong, Lin Ya, Cheng Wenli, Yuan Hui, Hao Sufang, Zhou Houqing, Zhao Qiuping, Xu Poshi, Wu Wei, Zhang Zhenlu, Zhou Weiyan, Li Qifu, Cai Jun, Zhou Zhou. New insights in primary aldosteronism diagnosis: a prospective multicenter study.. Clinical chemistry and laboratory medicine. 2026. DOI: 10.1515/cclm-2026-0579.