DOI 10.1016/j.redar.2020.01.015
Transfusional optimization in liver transplant using viscoelastic test guided therapy.
Аннотация
BACKGROUND
Assess the reduction of packed red blood cells (PRBCs) transfusion in liver transplantation (LT) after the introduction of the thromboelastometry as intraoperative coagulation monitor.
METHODS
We conducted a retrospective cohort study (n=92), randomized into two groups: groupA (control), in whom transfusion therapy was based on conventional laboratory tests (CLT), and groupB (ROTEM), whose blood transfusion was performed as protocolized algorithms, guided by thromboelastometry (ROTEM). We analyzed packed red blood cells (PRBCs) units, transfused units of fresh frozen plasma (FFP), platelets units, fibrinogen and tranexamic acid. We used the chi square test for the comparison of proportions and Student's t test to compare means when the distribution was normal. Otherwise, Mann-Whitney U test was performed.
RESULTS
In groupA 84.8% of patients required transfusion of PRBCs, with a median (IQR) of 4 (1.5-6), compared with 67.4% in groupB with a median (IQR) of 2 (0-4) (P<.05). We also found differences in the following variables: FFP transfusion rate was 84.8% with a median (IQR) of 5 (2-12) IU in groupA and 56.5% (median (IQR) of 1 (0-4.5) in B (P<.001) and in the fibrinogen administration, that was 6.5% in groupA and 34.8% in groupB (P<.01). Backward stepwise logistic regression model showed associations between the clamping time, the preoperative hemoglobin, the portal hypertension (PHT) and being or not in the treatment group and the need for perioperative transfusion. We didn't find significant differences in the incidence of complication during the early postoperative period between the two groups.
CONCLUSIONS
The introduction of thromboelastometry (ROTEM) measurements in hemostatic therapy algorithms reduces the transfusion rate of FFP and PRBCs during liver transplantation. The using of ROTEM derived thresholds leads to detecting higher requirements of fibrinogen compared to conventional laboratory tests.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.