Endoscopic ultrasound · 2021
Technical feasibility and safety of one-step deployment of EUS-guided hepaticogastrostomy using an 8-mm diameter metal stent with a fine-gauge stent delivery system (with video).
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ogura Takeshi, Ueno Saori, Okuda Atsushi, Nishioka Nobu, Yamada Masanori, Matsuno Jun, Ueshima Kazuya, Yamamoto Yoshitaro, Higuchi Kazuhide
Аннотация
BACKGROUND AND OBJECTIVES: Adverse events (AEs) such as bile peritonitis or pneumoperitoneum might occur during procedural steps for EUS-guided hepaticogastrostomy (HGS), such as during device exchange and after fistula dilation until stent deployment. Reducing the steps to the EUS-HGS procedure might therefore be ideal to prevent the occurrence of AEs. Recently, a novel, fully covered self-expandable metal stent (FCSEMS) has become available. Because of the fine-gauge stent delivery system (5.9Fr), fistula dilation might not be needed before stent deployment during EUS-HGS. The aim of this pilot study was to evaluate the technical feasibility and safety of one-step EUS-HGS using a novel 8-mm diameter FCSEMS.
PATIENTS AND METHODS: The primary outcome in this study was technical success, and the secondary outcomes were procedure- and stent-related AEs and clinical success. The technical success of one-step EUS-HGS was defined as successful FCSEMS deployment without any fistula dilation. Procedure time was measured from scope insertion to successful FCSEMS deployment.
RESULTS: One-step EUS-HGS using the novel FCSEMS was attempted on 14 patients. Technical success with a short procedure time (median: 7 min) and clinical success were obtained in all patients. In addition, procedure-related AEs such as bleeding, bile peritonitis, and stent migration during the procedure were not observed in any patients.
CONCLUSIONS: One-step EUS-HGS using the novel FCSEMS with a fine-gauge stent delivery system is technically feasible and shortens the procedure time with no requirement for additional fistula dilation, resulting in a potential reduction in procedure-related AEs.
PATIENTS AND METHODS: The primary outcome in this study was technical success, and the secondary outcomes were procedure- and stent-related AEs and clinical success. The technical success of one-step EUS-HGS was defined as successful FCSEMS deployment without any fistula dilation. Procedure time was measured from scope insertion to successful FCSEMS deployment.
RESULTS: One-step EUS-HGS using the novel FCSEMS was attempted on 14 patients. Technical success with a short procedure time (median: 7 min) and clinical success were obtained in all patients. In addition, procedure-related AEs such as bleeding, bile peritonitis, and stent migration during the procedure were not observed in any patients.
CONCLUSIONS: One-step EUS-HGS using the novel FCSEMS with a fine-gauge stent delivery system is technically feasible and shortens the procedure time with no requirement for additional fistula dilation, resulting in a potential reduction in procedure-related AEs.