Медицинская библиотека · Endoscopic ultrasound · 2021

Technical feasibility and safety of one-step deployment of EUS-guided hepaticogastrostomy using an 8-mm diameter metal stent with a fine-gauge stent delivery system (with video).

Ogura Takeshi, Ueno Saori, Okuda Atsushi, Nishioka Nobu, Yamada Masanori, Matsuno Jun, Ueshima Kazuya, Yamamoto Yoshitaro, Higuchi Kazuhide

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVES

Adverse events (AEs) such as bile peritonitis or pneumoperitoneum might occur during procedural steps for EUS-guided hepaticogastrostomy (HGS), such as during device exchange and after fistula dilation until stent deployment. Reducing the steps to the EUS-HGS procedure might therefore be ideal to prevent the occurrence of AEs. Recently, a novel, fully covered self-expandable metal stent (FCSEMS) has become available. Because of the fine-gauge stent delivery system (5.9Fr), fistula dilation might not be needed before stent deployment during EUS-HGS. The aim of this pilot study was to evaluate the technical feasibility and safety of one-step EUS-HGS using a novel 8-mm diameter FCSEMS.

PATIENTS AND

METHODS

The primary outcome in this study was technical success, and the secondary outcomes were procedure- and stent-related AEs and clinical success. The technical success of one-step EUS-HGS was defined as successful FCSEMS deployment without any fistula dilation. Procedure time was measured from scope insertion to successful FCSEMS deployment.

RESULTS

One-step EUS-HGS using the novel FCSEMS was attempted on 14 patients. Technical success with a short procedure time (median: 7 min) and clinical success were obtained in all patients. In addition, procedure-related AEs such as bleeding, bile peritonitis, and stent migration during the procedure were not observed in any patients.

CONCLUSIONS

One-step EUS-HGS using the novel FCSEMS with a fine-gauge stent delivery system is technically feasible and shortens the procedure time with no requirement for additional fistula dilation, resulting in a potential reduction in procedure-related AEs.

Для цитирования: Ogura Takeshi, Ueno Saori, Okuda Atsushi, Nishioka Nobu, Yamada Masanori, Matsuno Jun, Ueshima Kazuya, Yamamoto Yoshitaro, Higuchi Kazuhide. Technical feasibility and safety of one-step deployment of EUS-guided hepaticogastrostomy using an 8-mm diameter metal stent with a fine-gauge stent delivery system (with video).. Endoscopic ultrasound. 2021. DOI: 10.4103/eus-d-20-00206.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.