Eosinophilic Reaction at the Time of Catheter Insertion Predicts Survival in Patients Initiating Peritoneal Dialysis.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Uchiyama Kiyotaka, Washida Naoki, Kusahana Ei, Nakayama Takashin, Morimoto Kohkichi, Itoh Hiroshi
Аннотация
INTRODUCTION: Despite excellent biocompatibility, insertion of silicone peritoneal dialysis (PD) catheters can induce minor foreign body reaction, affecting long-term patient outcomes. We evaluated the effect of eosinophilic reaction associated with PD catheter insertion on outcomes of patients initiating PD.
METHODS: Eosinophilic reaction to PD catheter insertion was defined as the ratio of peripheral blood eosinophil count at 1 week after insertion (E1W) to pre-insertion eosinophil count (E0), and the association of E1W/E0 with technique survival, peritonitis-free survival, and heart failure (HF)-related hospitalization-free survival was analyzed.
RESULTS: This retrospective cohort study included 116 patients (89 male patients) who underwent PD catheter insertion between January 2008 and June 2018 (61.3 ± 12.9 years). The follow-up duration was 46.2 (23.8-75.3) months. E1W was significantly higher than E0 (median, 333 vs. 234/μL, p < 0.001), with a median E1W/E0 of 1.54. The log-rank test showed that technique survival, peritonitis-free survival, and HF-related hospitalization-free survival were significantly better in patients with E1W/E0 < 1.54 than in those with E1W/E0 ≥ 1.54 (p = 0.002, <0.001, and <0.001, respectively). By the Cox regression analysis adjusted for age, sex, the Charlson comorbidity index, the estimated glomerular filtration rate, and the geriatric nutritional risk index, E1W/E0 remained a significant risk factor for technique failure, peritonitis, and hospitalization for HF (hazard ratio (HR) 1.68, p = 0.01; HR 2.19, p < 0.001; HR 2.15, p < 0.001, respectively).
CONCLUSION: Eosinophilic reaction at the time of PD catheter insertion is a novel marker that may predict outcomes in patients initiating PD.
METHODS: Eosinophilic reaction to PD catheter insertion was defined as the ratio of peripheral blood eosinophil count at 1 week after insertion (E1W) to pre-insertion eosinophil count (E0), and the association of E1W/E0 with technique survival, peritonitis-free survival, and heart failure (HF)-related hospitalization-free survival was analyzed.
RESULTS: This retrospective cohort study included 116 patients (89 male patients) who underwent PD catheter insertion between January 2008 and June 2018 (61.3 ± 12.9 years). The follow-up duration was 46.2 (23.8-75.3) months. E1W was significantly higher than E0 (median, 333 vs. 234/μL, p < 0.001), with a median E1W/E0 of 1.54. The log-rank test showed that technique survival, peritonitis-free survival, and HF-related hospitalization-free survival were significantly better in patients with E1W/E0 < 1.54 than in those with E1W/E0 ≥ 1.54 (p = 0.002, <0.001, and <0.001, respectively). By the Cox regression analysis adjusted for age, sex, the Charlson comorbidity index, the estimated glomerular filtration rate, and the geriatric nutritional risk index, E1W/E0 remained a significant risk factor for technique failure, peritonitis, and hospitalization for HF (hazard ratio (HR) 1.68, p = 0.01; HR 2.19, p < 0.001; HR 2.15, p < 0.001, respectively).
CONCLUSION: Eosinophilic reaction at the time of PD catheter insertion is a novel marker that may predict outcomes in patients initiating PD.