COVID-19 diagnosis by RT-qPCR in alternative specimens.

Gonçalves Cássia Cristina Alves, Barroso Shana Priscila Coutinho, Herlinger Alice Laschuk, Galliez Rafael de Mello, de Almeida Tailah Bernardo, Boullosa Lidia Theodoro, Nascimento Erica Ramos Dos Santos, de Almeida Jessica M, da Costa Raissa Mirella Dos Santos Cunha, da Paixão Tatiana Monteiro, Couceiro José Nelson Dos Santos Silva, Frauches Thiago Silva, de Souza Wilson Rodrigues, Costa Andréa Ribeiro, Faffe Débora Souza, Leitão Isabela de Carvalho, da Silva Bianca Ortiz, de Lira Guilherme Sant'Anna, de Almeida Isabela Labarba Carvalho, Ferreira Orlando da Costa, UFRJ-Covid19 Workgroup, Castiñeiras Terezinha Marta Pereira Pinto, Mariani Diana, Tanuri Amilcar

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The high demand for adequate material for the gold standard reverse transcription real-time polymerase chain reaction (RT-qPCR)-based diagnosis imposed by the Coronavirus disease 2019 (COVID-19) pandemic, combined with the inherent contamination risks for healthcare workers during nasopharyngeal swab (NP) sample collection and the discomfort it causes patients, brought the need to identify alternative specimens suitable for the diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2).

OBJECTIVES

The aim of this work was to compare saliva and gingival fluid swabs to NP swabs as specimens for RT-qPCR-based SARS-CoV-2 diagnosis.

METHODS

We compared gingival fluid swabs (n = 158) and saliva (n = 207) to the rayon-tipped NP swabs obtained from mild-symptomatic and asymptomatic subjects as specimens for RT-qPCR for SARS-CoV-2 detection.

FINDINGS: When compared to NP swabs, gingival fluid swabs had a concordance rate of 15.4% among positive samples, zero among inconclusive, and 100% among negative ones. For saliva samples, the concordance rate was 67.6% among positive samples, 42.9% among inconclusive, and 96.8% among negative ones. However, the concordance rate between saliva and NP swabs was higher (96.9%) within samples with lower cycle threshold (Ct) values (Ct > 10 ≤ 25).

MAIN

CONCLUSIONS

Our data suggests that whereas gingival fluid swabs are not substitutes for NP swabs, saliva might be considered whenever NP swabs are not available or recommended.

Для цитирования: Gonçalves Cássia Cristina Alves, Barroso Shana Priscila Coutinho, Herlinger Alice Laschuk, Galliez Rafael de Mello, de Almeida Tailah Bernardo, Boullosa Lidia Theodoro, Nascimento Erica Ramos Dos Santos, de Almeida Jessica M, da Costa Raissa Mirella Dos Santos Cunha, da Paixão Tatiana Monteiro, Couceiro José Nelson Dos Santos Silva, Frauches Thiago Silva, de Souza Wilson Rodrigues, Costa Andréa Ribeiro, Faffe Débora Souza, Leitão Isabela de Carvalho, da Silva Bianca Ortiz, de Lira Guilherme Sant'Anna, de Almeida Isabela Labarba Carvalho, Ferreira Orlando da Costa, UFRJ-Covid19 Workgroup, Castiñeiras Terezinha Marta Pereira Pinto, Mariani Diana, Tanuri Amilcar. COVID-19 diagnosis by RT-qPCR in alternative specimens.. Memorias do Instituto Oswaldo Cruz. 2021. DOI: 10.1590/0074-02760210085.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.