MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s40291-021-00547-1

Медицинская библиотека · Molecular diagnosis & therapy · 2021

Analytical and Clinical Performance of Droplet Digital PCR in the Detection and Quantification of SARS-CoV-2.

Kim Kyoung Bo, Choi Hayoung, Lee Gun Dong, Lee Jaewoong, Lee Seungok, Kim Yonggoo, Cho Sung-Yeon, Lee Dong-Gun, Kim Myungshin

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

Since the initial coronavirus disease outbreak in late 2019 (COVID-19), reverse-transcription real-time polymerase chain reaction (RT-qPCR) has become the gold standard test to detect severe acute respiratory syndrome-related coronavirus 2 (SARS-CoV-2). However, a more sensitive and accurate diagnostic tool was required. Therefore, droplet digital polymerase chain reaction (ddPCR) was suggested as an alternative method. Here, we evaluated the performance of ddPCR to detect SARS-CoV-2 and compared it to the performance of RT-qPCR.

METHODS

The analytical performances, including limit of blank and limit of detection, were established using positive and negative SARS-CoV-2 reference materials. A total of 366 RNA extracts (173 positive and 193 negative by RT-qPCR) were collected from four institutions and tested with a Bio-Rad SARS-CoV-2 ddPCR kit that detects the SARS-CoV-2 genome using primers for N1 and N2.

RESULTS

Limit of blank was set at 0, and the limits of detection of N1 and N2 were 1.99 copies/μL and 5.18 copies/μL, respectively. Linearity was evaluated using serial dilution samples, which demonstrated good results (R2: 0.999, linear range: 5.88-6825.25 copies/μL for N1 and R2: 0.999, 5.53-5855.47 copies/μL for N2). The results of ddPCR and RT-qPCR revealed substantial agreement (Cohen's kappa: 0.639, p < 0.01). The 63 samples with positive ddPCR but negative RT-qPCR showed low copy numbers, and 55% of them had COVID-19-related symptoms.

CONCLUSIONS

Droplet digital polymerase chain reaction demonstrated excellent sensitivity for SARS-Cov-2 detection and consistently agreed with the results from conventional RT-qPCR. Furthermore, ddPCR provided quantitative data that can be used to monitor changes in the viral load of patients with COVID-19.

Для цитирования: Kim Kyoung Bo, Choi Hayoung, Lee Gun Dong, Lee Jaewoong, Lee Seungok, Kim Yonggoo, Cho Sung-Yeon, Lee Dong-Gun, Kim Myungshin. Analytical and Clinical Performance of Droplet Digital PCR in the Detection and Quantification of SARS-CoV-2.. Molecular diagnosis & therapy. 2021. DOI: 10.1007/s40291-021-00547-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.