MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mp.17677

Медицинская библиотека · Medical physics · 2025

Asymmetry analysis of nuclear Overhauser enhancement effect at -1.6 ppm in ischemic stroke.

Zhao Yu, Afzal Aqeela, Zu Zhongliang

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The nuclear Overhauser enhancement (NOE)-mediated saturation transfer effect at -1.6 ppm, termed NOE(-1.6 ppm), has demonstrated potential for detecting ischemic stroke. However, the quantification of the NOE(-1.6 ppm) effect usually relies on a multiple-pool Lorentzian fit method, which necessitates a time-consuming acquisition of the entire chemical exchange saturation transfer (CEST) Z-spectrum with high-frequency resolution, thus hindering its clinical applications.

PURPOSE: This study aims to assess the feasibility of employing asymmetry analysis, a rapid CEST data acquisition and analysis method, for quantifying the NOE(-1.6 ppm) effect in an animal model of ischemic stroke.

METHODS

We examined potential contaminations from guanidinium/amine CEST, NOE(-3.5 ppm), and asymmetric magnetization transfer (MT) effects, which could reduce the specificity of the asymmetry analysis of NOE(-1.6 ppm). First, a Lorentzian difference (LD) analysis was used to mitigate direct water saturation and MT effects, providing separate estimations of the contributions from the guanidinium/amine CEST and NOE effects. Then, the asymmetry analysis of the LD fitted spectrum was compared with the asymmetry analysis of the raw CEST Z-spectrum to evaluate the contribution of the asymmetric MT effect at -1.6 ppm.

RESULTS

Results show that the variations of the LD quantified NOE(-1.6 ppm) in stroke lesions are much greater than that of the CEST signals at +1.6 ppm and NOE(-3.5 ppm), suggesting that NOE(-1.6 ppm) has a dominating contribution to the asymmetry analysis at -1.6 ppm compared with the guanidinium/amine CEST and NOE(-3.5 ppm) in ischemic stroke. The NOE(-1.6 ppm) variations in the asymmetry analysis of the raw CEST Z-spectrum are close to those in the asymmetry analysis of the LD fitted spectrum, revealing that the NOE(-1.6 ppm) dominates over the asymmetric MT effects.

CONCLUSION

Our study demonstrates that the asymmetry analysis can quantify the NOE(-1.6 ppm) contrast in ischemic stroke with high specificity, thus presenting a viable alternative for rapid mapping of ischemic stroke.

Для цитирования: Zhao Yu, Afzal Aqeela, Zu Zhongliang. Asymmetry analysis of nuclear Overhauser enhancement effect at -1.6 ppm in ischemic stroke.. Medical physics. 2025. DOI: 10.1002/mp.17677.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.