MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/atm.2020.02.97

Медицинская библиотека · Annals of translational medicine · 2020

Robotic assisted nephrectomy for living kidney donation (RANLD) with use of multiple locking clips or ligatures for renal vascular closure.

Brunotte Maximilian, Rademacher Sebastian, Weber Justine, Sucher Elisabeth, Lederer Andri, Hau Hans-Michael, Stolzenburg Jens-Uwe, Seehofer Daniel, Sucher Robert

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Robotic assisted nephrectomy for living donation (RANLD) is a rapid emerging surgical technique competing for supremacy with totally laparoscopic and laparoscopic hand assisted techniques. Opinions about the safety of specific techniques of vascular closure in minimally invasive living kidney donation are heterogeneous and may be different for laparoscopic and robotic assisted surgical techniques.

METHODS

We retrospectively analyzed perioperative and short-term outcomes of our first (n=40) RANLD performed with the da Vinci Si surgical platform. Vascular closure of renal vessels was performed by either double clipping or a combination of clips and non-transfixing suture ligatures.

RESULTS

RANLD almost quintupled in our center for the observed time period. A total of n=21 (52.5%) left and n=19 (47.5%) right kidneys were procured. Renal vessel sealing with two locking clips was performed in 18 cases (45%) Both, clips and non-transfixing ligatures were used in 22 cases (55%). Mean donor age was 53.075±11.68 years (range, 28-70). The average total operative time was 150.75±27.30 min. Right donor nephrectomy (139±22 min) was performed significantly faster than left (160.95±27.93 min, P=0.01). Warm ischemia time was similar for both vascular sealing techniques and did not differ between left and right nephrectomies. No conversion was necessary. Clavien-Dindo Grade ≤IIIb complications occurred in (n=5) 12.5%. Grade IV and V complications did not develop. In particular no hemorrhage occurred using multiple locking clips or suture ligatures for renal vascular closure. Mortality was 0%. Thirteen kidneys (32.5%) were transplanted across the AB0 barrier.

CONCLUSIONS

RANLD is an emerging minimally invasive surgical technique which facilitates excellent perioperative and short-term outcomes also when using multiple locking clips or suture ligatures for renal vascular closure.

Для цитирования: Brunotte Maximilian, Rademacher Sebastian, Weber Justine, Sucher Elisabeth, Lederer Andri, Hau Hans-Michael, Stolzenburg Jens-Uwe, Seehofer Daniel, Sucher Robert. Robotic assisted nephrectomy for living kidney donation (RANLD) with use of multiple locking clips or ligatures for renal vascular closure.. Annals of translational medicine. 2020. DOI: 10.21037/atm.2020.02.97.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.