Development of a new suction instrument to reduce surgical smoke exposure in the operating room.

Chen Weiwei, Lei Lumin, Xiao Mingzi, Chen Qiaoling, Ma Yanlan

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To remove surgical smoke and its toxic components, we developed a novel smoke removal tube nested with the intraoperative suction tube, enabling convenient application during surgery and reducing hazards of surgical smoke exposure to medical staff.

METHODS

Standardized cuts with an electric knife were performed on pig dorsal tissue in an animal laboratory operating room without vertical laminar flow. The generated surgical fumes were analyzed using microcomputer laser dust meter counters for real-time monitoring of particulate matter 2.5 μm (PM2.5). Three new design suction tubes with different orifice diameters (1.5, 2.0, and 2.5 mm), each connected to local smoke evacuation, were compared with a conventional instrument without smoke evacuation.

RESULTS

The PM2.5 levels were significantly reduced with all three new tools, with smoke reduction rates of 24.20%, 66.86%, and 43.02%, respectively. Ten seconds after cutting, the 2.0-mm-diameter suction tube demonstrated lower PM2.5 concentrations compared with the other two groups, and the difference was statistically significant (P < 0.05).

CONCLUSION

This study is the first to develop an "all-in-one" surgical smoke device that enables simultaneous suction of smoke and blood with one hand. Among the tested tools, the 2.0-mm-diameter instrument is the best one. These results promote the use of local smoke evacuation and may inspire other surgeons to further innovation in this field.

Для цитирования: Chen Weiwei, Lei Lumin, Xiao Mingzi, Chen Qiaoling, Ma Yanlan. Development of a new suction instrument to reduce surgical smoke exposure in the operating room.. Frontiers in medical technology. 2026. DOI: 10.3389/fmedt.2026.1796828.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.