MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-2008-1038730

Медицинская библиотека · The Thoracic and cardiovascular surgeon · 2008

Tricuspid valve replacement: an analysis of risk factors and outcomes.

Civelek A, Ak K, Akgün S, Isbir S C, Arsan S

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Tricuspid valve replacement (TVR) is rarely performed and is associated with a high morbidity and mortality. We report our experience with TVR and related adverse events.

METHODS

Between January 1996 and December 2007, 35 patients underwent TVR with mechanical (n = 33) or bioprosthetic (n = 2) valves. Twenty-nine patients underwent concomitant cardiac procedures.

RESULTS

All patients completed follow-up (mean 47 months). Thirty-day mortality was 20 % (n = 7). Risk factors included perioperative low arterial blood pressure ( P = 0.000), New York Heart Association (NYHA) functional class III or IV ( P = 0.001), severe pulmonary hypertension (pulmonary arterial pressure greater than 60 mmHg) ( P = 0.000), hepatic dysfunction ( P = 0.000), ascites ( P = 0.003), and reoperation ( P = 0.015). Late mortality occurred in five patients. Valve-related complications included bleeding (n = 1) and stroke (n = 1). Kaplan-Meier estimates of 1-, 5- and 10-year survival (including early mortality) and event-free survival were 77.1 %, 60 %, and 54.3 % and 91.1 %, 80.6 %, and 55.9 %, respectively. Severe pulmonary hypertension was the only predictor of late mortality ( P = 0.001). Among survivors, the mean NYHA class improved from 2.8 to 1.1 ( P = 0.000).

CONCLUSIONS

Although early outcome after TVR is suboptimal, long-term survival and functional improvement is satisfactory.

Для цитирования: Civelek A, Ak K, Akgün S, Isbir S C, Arsan S. Tricuspid valve replacement: an analysis of risk factors and outcomes.. The Thoracic and cardiovascular surgeon. 2008. DOI: 10.1055/s-2008-1038730.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.