MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circinterventions.108.800607

Медицинская библиотека · Circulation. Cardiovascular interventions · 2008

Retrograde transarterial implantation of a nonmetallic aortic valve prosthesis in high-surgical-risk patients with severe aortic stenosis: a first-in-man feasibility and safety study.

Schofer Joachim, Schlüter Michael, Treede Hendrik, Franzen Olaf W, Tübler Thilo, Pascotto Andrea, Low Reginald I, Bolling Steven F, Meinertz Thomas, Reichenspurner Hermann

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

To assess the feasibility and safety of retrograde transarterial implantation of a novel nonmetallic aortic valve prosthesis (Direct Flow Medical Inc, Santa Rosa, Calif), a prospective single-center study was performed in patients with severe aortic stenosis at high risk for open-heart surgery.

METHODS AND

RESULTS

Fifteen patients (intention-to-treat cohort) with an aortic valve area < or = 0.8 cm(2), a > or = 35-mm Hg mean transvalvular pressure gradient, and a logistic EuroSCORE > or = 20% were enrolled. Percutaneous aortic valve replacement was performed with the patient under general anesthesia. Hemodynamic parameters were assessed before and after implantation by transesophageal echocardiography. Clinical follow-up and transthoracic echocardiographic assessment were obtained at 30 days. Procedural success was achieved in 12 patients (80%). Surgical conversion became necessary at day 2 in 1 patient; 11 patients (73%) were discharged with a permanent implant. In these patients, implantation resulted acutely in a significant increase in aortic valve area (median, 1.64 [interquartile range, 1.27 to 1.74] versus 0.60 [0.46 to 0.69] cm(2); P = 0.0033) and a concomitant reduction in the mean pressure gradient (14.0 [13.2 to 16.5] versus 54.0 [43.2 to 59.8] mm Hg; P = 0.0033). At 30 days, 1 cardiac death (6.7%; 95% CI, 0.2% to 32.0%) and 1 major stroke were observed. The 10 surviving patients with a permanent implant showed marked hemodynamic and clinical improvement at this time point.

CONCLUSIONS

In this small series of patients, percutaneous implantation of the Direct Flow Medical aortic valve prosthesis in high-surgical-risk patients was feasible and associated with a reasonably low safety profile.

Для цитирования: Schofer Joachim, Schlüter Michael, Treede Hendrik, Franzen Olaf W, Tübler Thilo, Pascotto Andrea, Low Reginald I, Bolling Steven F, Meinertz Thomas, Reichenspurner Hermann. Retrograde transarterial implantation of a nonmetallic aortic valve prosthesis in high-surgical-risk patients with severe aortic stenosis: a first-in-man feasibility and safety study.. Circulation. Cardiovascular interventions. 2008. DOI: 10.1161/circinterventions.108.800607.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.