DOI 10.1093/europace/eun072

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2008

Dual-chamber defibrillators reduce clinically significant adverse events compared with single-chamber devices: results from the DATAS (Dual chamber and Atrial Tachyarrhythmias Adverse events Study) trial.

Almendral Jesus, Arribas Fernando, Wolpert Christian, Ricci Renato, Adragao Pedro, Cobo Erik, Navarro Xavier, Quesada Aurelio, DATAS Steering Committee, DATAS Writing Committee, DATAS Investigators

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: This randomized trial evaluated clinically significant adverse events (CSAEs), in patients implanted with dual-chamber (DC) vs. single-chamber (SC) implantable cardioverter defibrillator (ICD). DC-ICD had atrial tachyarrhythmia (AT) therapy capabilities. Strict programming recommendations were reinforced.

METHODS AND

RESULTS

Patients with conventional SC-ICD indication were randomized to DC-ICD, SC-ICD, or a DC-ICD programmed as an SC-ICD (SC-simulated) and followed for 16 months. Patients in the DC and SC-simulated groups crossed over after 8 months. The primary endpoint was a composite of CSAE: all-cause mortality; invasive intervention; hospitalization (> 24 h) for cardiovascular causes; inappropriate shocks (two or more episodes); and sustained symptomatic AT lasting > 48 h. The outcome variable was a pre-specified score that corrected for clinical severity and follow-up duration. Three hundred and thirty-four patients were analysed (DC-ICD, n = 112; SC-ICD, n = 111; SC-simulated, n = 111). The mean left ventricular ejection fraction was 0.36 +/- 0.13, 69% were in functional class > or = II. CSAE occurred in 65 DC-ICD, 82 SC-ICD, and 84 SC-simulated patients. The outcome variable was 33% lower in the DC-ICD group (OR 0.31; 95% CI 0.14-0.67; P = 0.0028). Mortality was 4% in DC, 9% in SC, and 10% in SC-simulated.

CONCLUSION

In patients with a standard SC-ICD indication, DC-ICD was associated with less CSAE when compared with SC-ICD.

Для цитирования: Almendral Jesus, Arribas Fernando, Wolpert Christian, Ricci Renato, Adragao Pedro, Cobo Erik, Navarro Xavier, Quesada Aurelio, DATAS Steering Committee, DATAS Writing Committee, DATAS Investigators. Dual-chamber defibrillators reduce clinically significant adverse events compared with single-chamber devices: results from the DATAS (Dual chamber and Atrial Tachyarrhythmias Adverse events Study) trial.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2008. DOI: 10.1093/europace/eun072.