MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjcard.2020.09.055

Медицинская библиотека · The American journal of cardiology · 2020

Relation of Peripheral Venous Pressure to Central Venous Pressure in Patients With Heart Failure, Heart Transplant, and Left Ventricular Assist Device.

Vlismas Peter P, Wiesenfeld Elliot, Oh Kyung Taek, Murthy Sandhya, Vukelic Sasha, Saeed Omar, Patel Snehal, Shin Jooyoung J, Jorde Ulrich P, Sims Daniel B

СтатьяПеревод пока не подготовлен

Аннотация

Peripheral venous pressure (PVP) monitoring is a noninvasive method to assess volume status. We investigated the correlation between PVP and central venous pressure (CVP) in heart failure (HF), heart transplant (HTx), and left ventricular assist device (LVAD) patients undergoing right heart catheterization (RHC). A prospective, cross-sectional study examining PVP in 100 patients from October 2018 to January 2020 was conducted. The analysis included patients undergoing RHC admitted for HF, post-HTx monitoring, or LVAD hemodynamic testing. Sixty percent of patients had HF, 30% were HTx patients, and 10% were LVAD patients. The mean PVP was 9.4 ± 5.3 mm Hg, and the mean CVP was 9.2 ± 5.8 mm Hg. The PVP and CVP were found to be highly correlated (r = 0.93, p < 0.00001). High correlation was also noted when broken down by HF (r = 0.93, p < 0.00001), HTx (r = 0.93, p < 0.00001), and LVAD groups (r = 0.94, p < 0.00005). In conclusion, there is a high degree of correlation between PVP and CVP in HF, HTx, and LVAD patients. PVP measurements can be used as a rapid, reliable, noninvasive estimate of volume status in these patient populations.

Для цитирования: Vlismas Peter P, Wiesenfeld Elliot, Oh Kyung Taek, Murthy Sandhya, Vukelic Sasha, Saeed Omar, Patel Snehal, Shin Jooyoung J, Jorde Ulrich P, Sims Daniel B. Relation of Peripheral Venous Pressure to Central Venous Pressure in Patients With Heart Failure, Heart Transplant, and Left Ventricular Assist Device.. The American journal of cardiology. 2020. DOI: 10.1016/j.amjcard.2020.09.055.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.