Archives of cardiovascular diseases · 2020
Long-term evolution of stents implanted in branch pulmonary arteries.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ma Iris, El Arid Jean-Marc, Neville Paul, Soule Nathalie, Dion Fanny, Poinsot Jacques, Chantepie Alain, Lefort Bruno
Аннотация
BACKGROUND: Branch pulmonary artery stenosis complicates the management of congenital heart diseases. Surgical branch pulmonary artery angioplasty is associated with a high reintervention rate. As an alternative, percutaneous or intraoperative branch pulmonary artery stents have been implanted to improve efficiency, but long-term evaluations are limited.
AIM: To describe the long-term evolution of branch pulmonary artery stents.
METHODS: We conducted a retrospective cohort study at Tours University Hospital. All stents implanted by surgery or catheterization in branch pulmonary arteries with a minimum follow-up of 12 months and at least one catheterization control were included. The primary endpoint combined cardiovascular mortality, surgical or percutaneous reintervention for stent complication or new stent implantation.
RESULTS: Between 2007 and 2017, 76 stents in 51 patients were included (62 stents implanted by surgery, 14 by catheterization). At implantation, the patients' mean age and weight were 4.7years (interquartile range 4.2years) and 17.3kg (interquartile range 11.0kg), respectively. Mean branch pulmonary artery minimum diameter was 4.1±2.1mm (mean Z-score-4.9±2.9), and mean initial stent diameter was 9.1±3.1mm. During a follow-up of 5.3years (range 0-11.2 years), freedom from primary endpoint was 86.8% (95% confidence interval 79.6-94.8%) at 1 year, 71.5% (95% confidence interval 61.9-82.7%) at 5years and 69.6% (95% confidence interval 59.6-81.2%) at 10 years. We did not identify any factors associated with major adverse cardiovascular events. Among stents without major adverse cardiovascular events, the mean branch pulmonary artery diameter Z-score at last evaluation had increased by +4.8±3.2 compared with the initial diameter (P<0.001). After stent implantation, a median of 2 re-expansions were performed for each stent (range 0-7).
CONCLUSIONS: Stent implantation should offer a good long-term solution for branch pulmonary artery stenosis, although iterative re-expansions are required.
AIM: To describe the long-term evolution of branch pulmonary artery stents.
METHODS: We conducted a retrospective cohort study at Tours University Hospital. All stents implanted by surgery or catheterization in branch pulmonary arteries with a minimum follow-up of 12 months and at least one catheterization control were included. The primary endpoint combined cardiovascular mortality, surgical or percutaneous reintervention for stent complication or new stent implantation.
RESULTS: Between 2007 and 2017, 76 stents in 51 patients were included (62 stents implanted by surgery, 14 by catheterization). At implantation, the patients' mean age and weight were 4.7years (interquartile range 4.2years) and 17.3kg (interquartile range 11.0kg), respectively. Mean branch pulmonary artery minimum diameter was 4.1±2.1mm (mean Z-score-4.9±2.9), and mean initial stent diameter was 9.1±3.1mm. During a follow-up of 5.3years (range 0-11.2 years), freedom from primary endpoint was 86.8% (95% confidence interval 79.6-94.8%) at 1 year, 71.5% (95% confidence interval 61.9-82.7%) at 5years and 69.6% (95% confidence interval 59.6-81.2%) at 10 years. We did not identify any factors associated with major adverse cardiovascular events. Among stents without major adverse cardiovascular events, the mean branch pulmonary artery diameter Z-score at last evaluation had increased by +4.8±3.2 compared with the initial diameter (P<0.001). After stent implantation, a median of 2 re-expansions were performed for each stent (range 0-7).
CONCLUSIONS: Stent implantation should offer a good long-term solution for branch pulmonary artery stenosis, although iterative re-expansions are required.