m+Medelevator.RU
← Поиск публикаций
Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2023

Evaluation of [68Ga]-DOTATOC PET/MRI in Patients with Meningioma of the Subcranial and Intraorbital Space.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Milosevic Aleksandar, Styczen Hanna, Grueneisen Johannes, Li Yan, Weber Manuel, Fendler Wolfgang P, Kirchner Julian, Damman Philipp, Wrede Karsten, Lazaridis Lazaros, Glas Martin, Guberina Maja, Eckstein Anja, Blau Tobias, Herrmann Ken, Umutlu Lale, Forsting Michael, Deuschl Cornelius, Schaarschmidt Benedikt

Аннотация

Meningiomas are known to express somatostatin receptor (SSTR) type 2 to a high degree. Therefore, radiolabeled somatostatin analogs, such as DOTATOC, have been introduced for PET imaging of meningiomas. However, the benefit of hybrid SSTR PET/MRI is still debated. Here, we report our experience with [68Ga]-DOTATOC PET/MRI. Methods: PET/MRI was performed in 60 patients with suspected or diagnosed meningiomas of the skull plane and eye socket. Acquired datasets were reported by 2 independent readers regarding local tumor extent and signal characteristics. Histopathologic results and follow-up imaging served as the reference standard. SUVs of target lesions were analyzed according to the corresponding maximal tracer uptake. The diagnostic accuracy of PET/MRI and conventional MRI was determined independently and compared with the reference standard. Results: In total, 60 target lesions were identified, with 54 considered to be meningiomas according to the reference standard. Sensitivity and specificity of PET/MRI versus MRI alone were 95% versus 96% and 75% versus 66%, respectively. The McNemar test was not able to distinguish any differences between PET/MRI and the reference standard or MRI and the reference standard. No differences were found between the 2 modalities with respect to local infiltration. Conclusion: SSTR PET/MRI and MRI yielded similar accuracy for the detection of meningiomas of the skull base and intraorbital space. Here, sequential low-dose SSTR PET/CT might be helpful for the planning of radioligand therapy or radiotherapy.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты