MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejogrb.2019.10.016

Медицинская библиотека · European journal of obstetrics, gynecology, and reproductive biology · 2019

Comparison of cervical length measured by POP-Q C-D and MRI: Why is POP-Q C-D not accurate?

Tang Lian, Liao Kedan, Jiang Wenxuan, Feng Jie, Liu Ping, Chen Chunlin

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To investigate the relationship between the cervical length evaluated by Pelvic Organ Prolapse Quantification (POP-Q) point C minus D (C-D; ECL) and the magnetic resonance imaging (MRI)-based cervical length (MCL).

STUDY

DESIGN

This was a retrospective study of patients with POP II-IV who underwent MRI. The ECL was calculated based on the absolute value of C-D according to POP-Q. The MCL was defined as the distance between the internal and external cervical os on MRI. Intraobserver reliability using the Bland-Altman method. Continuous variables were compared by paired 2-tailed t-tests. Multiple linear regression analysis was used to analyse the factors influencing differences between the ECL and MCL.

RESULTS

Among 105 eligible patients, 89 patients were eventually included in the study. The Bland-Altman scatter plots show that the intraobserver reliability of MCL was excellent. Furthermore, the mean ECL was significantly longer than the mean MCL (48.15 mm ± 27.46 vs. 28.25 mm ± 10.27, P = 0.000).Body mass index, parity, menopausal status or total vaginal length did not affect the difference between ECL and MCL. However, The larger the point Ba, the larger the difference between the ECL and MCL. The larger the point Bp, the smaller the difference between the ECL and MCL.

CONCLUSION

In general, POP-Q C-D was longer than the cervical length measured by MRI. Deep analysis found that when uterine prolapse is combined with larger anterior vaginal wall prolapse, the difference between ECL and MCL is greater; when uterine prolapse with larger posterior vaginal wall prolapse, the difference between ECL and MCL is smaller.

Для цитирования: Tang Lian, Liao Kedan, Jiang Wenxuan, Feng Jie, Liu Ping, Chen Chunlin. Comparison of cervical length measured by POP-Q C-D and MRI: Why is POP-Q C-D not accurate?. European journal of obstetrics, gynecology, and reproductive biology. 2019. DOI: 10.1016/j.ejogrb.2019.10.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.