MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.nucmedbio.2012.11.011

Медицинская библиотека · Nuclear medicine and biology · 2013

Equivalence of arterial and venous blood for [11C]CO2-metabolite analysis following intravenous administration of 1-[11C]acetate and 1-[11C]palmitate.

Ng Yen, Moberly Steven P, Mather Kieren J, Brown-Proctor Clive, Hutchins Gary D, Green Mark A

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Sampling of arterial blood for metabolite correction is often required to define a true radiotracer input function in quantitative modeling of PET data. However, arterial puncture for blood sampling is often undesirable. To establish whether venous blood could substitute for arterial blood in metabolite analysis for quantitative PET studies with 1-[(11)C]acetate and 1-[(11)C]palmitate, we compared the results of [(11)C]CO2-metabolite analyses performed on simultaneously collected arterial and venous blood samples.

METHODS

Paired arterial and venous blood samples were drawn from anesthetized pigs at 1, 3, 6, 8, 10, 15, 20, 25 and 30min after i.v. administration of 1-[(11)C]acetate and 1-[(11)C]palmitate. Blood radioactivity present as [(11)C]CO2 was determined employing a validated 10-min gas-purge method. Briefly, total blood (11)C radioactivity was counted in base-treated [(11)C]-blood samples, and non-[(11)C]CO2 radioactivity was counted after the [(11)C]-blood was acidified using 6N HCl and bubbled with air for 10min to quantitatively remove [(11)C]CO2.

RESULTS

An excellent correlation was found between concurrent arterial and venous [(11)C]CO2 levels. For the [(11)C]acetate study, the regression equation derived to estimate the venous [(11)C]CO2 from the arterial values was: y=0.994x+0.004 (r(2)=0.97), and for the [(11)C]palmitate: y=0.964x-0.001 (r(2)=0.9). Over the 1-30min period, the fraction of total blood (11)C present as [(11)C]CO2 rose from 4% to 64% for acetate, and 0% to 24% for palmitate. The rate of [(11)C]CO2 appearance in venous blood appears similar for the pig model and humans following i.v. [(11)C]-acetate administration.

CONCLUSION

Venous blood [(11)C]CO2 values appear suitable as substitutes for arterial blood samples in [(11)C]CO2 metabolite analysis after administration of [(11)C]acetate or [(11)C]palmitate

ADVANCES IN KNOWLEDGE AND IMPLICATIONS FOR PATIENT CARE: Quantitative PET studies employing 1-[(11)C]acetate and 1-[(11)C]palmitate can employ venous blood samples for metabolite correction of an image-derived tracer arterial input function, thereby avoiding the risks of direct arterial blood sampling.

Для цитирования: Ng Yen, Moberly Steven P, Mather Kieren J, Brown-Proctor Clive, Hutchins Gary D, Green Mark A. Equivalence of arterial and venous blood for [11C]CO2-metabolite analysis following intravenous administration of 1-[11C]acetate and 1-[11C]palmitate.. Nuclear medicine and biology. 2013. DOI: 10.1016/j.nucmedbio.2012.11.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.