m+Medelevator.RU
← Поиск публикаций
The Journal of trauma · 2004

The appropriate diagnostic threshold for ventilator-associated pneumonia using quantitative cultures.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Croce Martin A, Fabian Timothy C, Mueller Eric W, Maish George O, Cox Jordy C, Bee Tiffany K, Boucher Bradley A, Wood G Christopher

Аннотация

BACKGROUND: The use of quantitative cultures of the bronchoalveolar lavage (BAL) effluent to distinguish between posttraumatic inflammatory response and ventilator-associated pneumonia (VAP) is becoming more common. However, the diagnostic threshold of either 10 or 10 colonies/mL remains debatable. Because mortality from VAP is related to treatment delay, some have chosen a lower diagnostic threshold (>10 colonies/mL). This may result in unnecessary antibiotic use with its sequelae: increased resistant organisms, antibiotic-related complications, and increased costs. The purpose of this study is to determine the optimal diagnostic threshold for VAP diagnosis using quantitative cultures of the BAL effluent.

METHODS: Data on patients with fiberoptic bronchoscopy with BAL are maintained in a prospectively collected database at our Level I trauma center. This database was reviewed for timing and frequency of BAL and the colony counts of each organism identified. Indication for bronchoscopy was clinical evidence of VAP. VAP was defined as >10 colonies/mL in the BAL effluent. A false-negative BAL was defined as any patient who had <10 colonies/mL and developed VAP with the same organism up to 7 days after the previous culture.

RESULTS: Over a 46-month period, 526 patients underwent 1,372 fiberoptic bronchoscopy procedures with BAL. Of these, 72% were male patients, 91% followed blunt injury, and mean age and Injury Severity Score were 43 years and 30, respectively. Overall mortality was 14%. There were 1,898 organisms identified (42% were gram-positive and 58% were gram-negative). VAP was diagnosed in 38% of BAL. Overall, there were 43 episodes in 38 patients defined as false-negative (3%). The false-negative rate was 9% in patients with 10 organisms. The most common false-negative organisms were Pseudomonas and Acinetobacter species.

CONCLUSION: The VAP diagnostic threshold for quantitative BAL in trauma patients should be >10 colonies/mL. One may consider a threshold of >10 colonies/mL in severely injured patients with Pseudomonas or Acinetobacter species.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты