DOI 10.1002/uog.5208

Медицинская библиотека · Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2008

Reproducibility of fetal renal pelvis volume measurement using three-dimensional ultrasound.

Duin L K, Willekes C, Vossen M, Beckers M, Offermans J, Nijhuis J G

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To assess the reproducibility of fetal renal pelvis volume measurement in hydronephrotic kidneys using transabdominal three-dimensional (3D) ultrasound.

METHODS

The fetal renal pelvis volume was measured using 3D ultrasound in one kidney in each of 15 fetuses with hydronephrosis in the second or third trimester of pregnancy. Hydronephrosis was diagnosed when the fetus had an anteroposterior renal pelvis diameter > or = 5 mm. After volume acquisition by one of the observers, the repeatability of volume calculation with manual delineation of the fetal renal pelvis was assessed by six different observers using the Virtual Organ Computer-aided AnaLysis (VOCAL(trade mark)) imaging program. The intraclass correlation coefficients (ICC), coefficient of variation (CV) and within- and between-observer repeatability coefficient (r) were calculated and Bland-Altman plots were constructed.

RESULTS

Both intra- and interobserver reliability of the fetal renal pelvis volume measurements were considered to be very good. For intraobserver reliability, the ICC was 0.996 and the CV was 10.8%. For the overall interobserver reliability, the ICC was 0.998 and the CV was 15.7%; the interobserver reliability between pairs of observers had ICCs between 0.994 and 0.999, and CVs between 19.5% and 7.6% for inexperienced and experienced observers, respectively.

CONCLUSION

With 3D ultrasound using the VOCAL imaging program, it is technically feasible to reproduce fetal renal pelvis volume measurements. Further research to establish the clinical applications of this technology is warranted.

Для цитирования: Duin L K, Willekes C, Vossen M, Beckers M, Offermans J, Nijhuis J G. Reproducibility of fetal renal pelvis volume measurement using three-dimensional ultrasound.. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2008. DOI: 10.1002/uog.5208.