MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.rct.0000230009.31715.5b

Медицинская библиотека · Journal of computer assisted tomography · 2006

Multislice computed tomography in planning nephron-sparing surgery in a prospective study with 76 patients: comparison of radiological and histopathological findings in the infiltration of renal structures.

Hallscheidt Peter, Wagener Nina, Gholipour Farshad, Aghabozorgi Nastaran, Dreyhaupt Jens, Hohenfellner Markus, Haferkamp Axel, Pfitzenmaier Jesco

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aim of this prospective study is to determine the diagnostic accuracy of multidetector-row computed tomography (CT) compared to histopathologic findings in tumor staging of renal cell carcinoma, with the focus on tumor stage, vein and artery infiltration, and infiltration of the renal pelvis.

MATERIALS AND

METHODS

In a prospective study, a total of 76 consecutive patients with suspected renal cell carcinoma were preoperatively assessed for tumor staging using multidetector-row CT. Triphasic CT imaging (i.e., noncontrast, arterial, and parenchymal phase) was performed using multidetector-row CT with reconstructed slice thicknesses of 2 and 5 mm. Two blinded readers evaluated the CT scans independently; the results were then correlated with the histopathologic results.

RESULTS

A total of 56 renal cell carcinomas were proven on histopathology. Readers 1 and 2 reached a sensitivity of 1.0 and 1.0 and a specificity of 0.41 and 0.42 for arterial infiltration, a sensitivity of 1.0 and 0.86 and a specificity of 0.58 and 0.5 for venous infiltration, and a sensitivity of 0.75 and 1.0 and a specificity of 0.5 and 0.44 for infiltration of the renal pelvis. The correlation between both readers was 0.7 for all modalities.

CONCLUSIONS

The multiplanar reconstruction capability of multidetector-row CT allowed good sensitivity in predicting arterial infiltration. The lowest specificity was reached in excluding infiltration of the renal pelvis. Despite its high temporal and spatial resolution, the capacity of multidetector CT to predict intrarenal infiltrations is still limited.

Для цитирования: Hallscheidt Peter, Wagener Nina, Gholipour Farshad, Aghabozorgi Nastaran, Dreyhaupt Jens, Hohenfellner Markus, Haferkamp Axel, Pfitzenmaier Jesco. Multislice computed tomography in planning nephron-sparing surgery in a prospective study with 76 patients: comparison of radiological and histopathological findings in the infiltration of renal structures.. Journal of computer assisted tomography. 2006. DOI: 10.1097/01.rct.0000230009.31715.5b.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.