Journal of manipulative and physiological therapeutics · 2012
Evaluation of changes in pelvic belt tension during 2 weight-bearing functional tasks.
Сравнительное исследованиеОценочное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Arumugam Ashokan, Milosavljevic Stephan, Woodley Stephanie, Sole Gisela
Аннотация
OBJECTIVE: The purposes of this study were to evaluate changes in pelvic belt tension during 2 weight-bearing functional tasks (transition from bipedal to unipedal stance [BUS] and walking) and to evaluate the reliability and the percentage variation for belt tension scores from trial to trial.
METHODS: A cross-sectional repeated-measures study was conducted with 10 healthy male participants (mean age, 28.3 ± 8.8years). Participants performed 10 trials of BUS and walking while wearing a nonelastic pelvic compression belt (PCB) applied distal to the anterior superior iliac spines, with a load cell positioned in the center of the belt. The load cell was calibrated using known weights (1-10kg) to define the relationship between the applied tension and voltage change (R(2) = 0.99). Load cell tension values were recorded in voltage signals and then converted to newtons of force using appropriate conversion values (0.012V = 10N). Mean and standard deviation values, intraclass correlation coefficients (ICC 3,1), and percentage standard error of measurements (% SEM) were analyzed for PCB tension recorded during the BUS and walking trials.
RESULTS: The mean tension achieved with a PCB was found to be 41.02 (±4.23) N during BUS and 44.07 (±5.80) N during walking. The trial-to-trial reliability (ICC 3,1) was high (ICC ≥0.9), and the variation in PCB tension across 10 trials (% SEM) was 4% or less.
CONCLUSION: The mean tension achieved during the tasks was 44 N or less. The reliability is high, and the variation is low across the trials, which implies that a PCB could be used to produce consistent effects during repetition of the tasks (BUS and walking).
METHODS: A cross-sectional repeated-measures study was conducted with 10 healthy male participants (mean age, 28.3 ± 8.8years). Participants performed 10 trials of BUS and walking while wearing a nonelastic pelvic compression belt (PCB) applied distal to the anterior superior iliac spines, with a load cell positioned in the center of the belt. The load cell was calibrated using known weights (1-10kg) to define the relationship between the applied tension and voltage change (R(2) = 0.99). Load cell tension values were recorded in voltage signals and then converted to newtons of force using appropriate conversion values (0.012V = 10N). Mean and standard deviation values, intraclass correlation coefficients (ICC 3,1), and percentage standard error of measurements (% SEM) were analyzed for PCB tension recorded during the BUS and walking trials.
RESULTS: The mean tension achieved with a PCB was found to be 41.02 (±4.23) N during BUS and 44.07 (±5.80) N during walking. The trial-to-trial reliability (ICC 3,1) was high (ICC ≥0.9), and the variation in PCB tension across 10 trials (% SEM) was 4% or less.
CONCLUSION: The mean tension achieved during the tasks was 44 N or less. The reliability is high, and the variation is low across the trials, which implies that a PCB could be used to produce consistent effects during repetition of the tasks (BUS and walking).
Предметные рубрики MeSH
AdultBiomechanical PhenomenaCross-Sectional StudiesExercise TestHumansJoint InstabilityMaleMonitoring, PhysiologicNew ZealandOrthotic DevicesPressureRange of Motion, ArticularReference ValuesReproducibility of ResultsSacroiliac JointSampling StudiesTask Performance and AnalysisWalkingWeight-BearingYoung Adult