DOI 10.1111/aos.70076

Медицинская библиотека · Acta ophthalmologica · 2026

Patient-reported outcome measures after non-diffractive extended range of field IOL implantation: PureSee versus Vivity.

Koh Kyungmin, Tuuminen Raimo, Na Dong Gyu, Jeon Sohee

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To perform a head-to-head comparison of two extended range of field intraocular lenses (IOLs) for their patient-reported outcome measures.

SETTING

Keye Eye Hospital, Seoul, Korea.

DESIGN

Clinical cohort study.

METHODS

Eighty-five emmetropic bilaterally operated patients (PureSee [N = 34] vs. AcrySof Vivity [N = 51]) were compared for their visual outcomes, dysphotopsia (scale 0-100), and spectacle-independent visual function index (VF)-14 questionnaire scores at the 6-month timepoint.

RESULTS

Baseline patient and ophthalmic variables were comparable between the groups. Acrysof Vivity provided better uncorrected near (0.21 ± 0.10 vs. 0.28 ± 0.07 LogMAR units, p < 0.001) and intermediate visual acuities (0.08 ± 0.09 vs. 0.22 ± 0.08 LogMAR units, p < 0.001) compared with PureSee. In contrast, contrast sensitivities in photopic (1.57 ± 0.14 vs. 1.45 ± 0.17 LogCWeber, p = 0.024) and mesopic conditions (1.30 ± 0.12 vs. 1.19 ± 0.17 LogCWeber, p = 0.025) were greater for PureSee than Acrysof Vivity. PureSee was associated with overall mean dysphotopsia scores (1.3 ± 3.2 vs. 5.8 ± 9.3, p = 0.009) significantly less than for Acrysof Vivity. Spectacle-independent VF-14 scores for visual acuities at near, specifically reading small print (76.0 ± 20.0 vs. 65.9 ± 22.4, p = 0.046), newspaper or a book (94.8 ± 11.5 vs. 80.3 ± 19.5, p < 0.001), and large-print or numbers on a telephone (88.0 ± 15.4 vs. 79.5 ± 18.2, p = 0.030) were significantly greater for Acrysof Vivity than PureSee, whereas overall mean spectacle-independent VF-14 scores remained statistically non-significant for the two IOLs (92.6 ± 5.7 vs. 89.3 ± 9.7, respectively; p = 0.115).

CONCLUSIONS

Acrysof Vivity was associated with greater spectacle-independent near visual acuity and visual function for reading, while PureSee outperformed in photopic and mesopic contrast sensitivities, glare, starburst, and overall dysphotopsia. Based on these pros and cons, optimal extended range of field IOL selection should be aligned with the individual's needs and concerns.

Для цитирования: Koh Kyungmin, Tuuminen Raimo, Na Dong Gyu, Jeon Sohee. Patient-reported outcome measures after non-diffractive extended range of field IOL implantation: PureSee versus Vivity.. Acta ophthalmologica. 2026. DOI: 10.1111/aos.70076.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.