MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.67.1.22

Медицинская библиотека · Investigative ophthalmology & visual science · 2026

Exploring Trial Endpoints in Geographic Atrophy Based on Localized Functional Changes in Microperimetry and AI-Quantified OCT Biomarkers.

Birner Klaudia, Mai Julia, Boryshchuk Daniela, Frommlet Florian, Enzendorfer Marie Louise, Schürer-Waldheim Simon, Gumpinger Markus, Vogl Wolf-Dieter, Leingang Oliver, Sacu Stefan, Schmidt-Erfurth Ursula

СтатьяКлиническое исследование III фазыРандомизированное исследованиеМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The introduction of novel therapeutics for geographic atrophy (GA) highlights the need to define functional correlates of high-risk optical coherence tomography (OCT) biomarkers, in particular retinal-pigment-epithelium (RPE) loss and ellipsoid zone (EZ) loss. We conducted a pointwise structure/function correlation between OCT-based markers and retinal sensitivity (RS) in microperimetry (MP) in GA.

METHODS

Patients from the phase III OAKS clinical trial (NCT03525613) examined by OCT (Heidelberg Spectralis) and Macular Integrity Assessment (MAIA, iCare, and Centervue) MP in a 68-point grid were analyzed. Deep-learning-(DL)-based algorithms quantified RPE, EZ loss, and EZ thickness from OCT. Co-registration between MP and OCT was established between each MP stimulus and OCT B-scan location. A multivariable mixed effect model was implemented to identify RS for each OCT biomarker, accounting for eccentricity.

RESULTS

Six hundred seventy-eight study and fellow eyes of 406 patients with 41,925 MP points were included. Mean RS was 17 ± 7 decibel (dB), 9 ± 7 dB, and 2 ± 6 dB in intact retina, EZ, and RPE loss, respectively. Increased EZ thickness improved RS by 0.2 dB/µm (95% confidence interval [CI] = 0.2 to 0.2, P < 0.001). In areas of EZ loss, RS was significantly reduced compared to intact retina (-8 dB, 95% CI = -9 to -8]), whereas RPE loss decreased RS by -14 dB (95% CI = -15 to -14), accounting for eccentricity (all P < 0.001).

CONCLUSIONS

A significant association between RS in MP and EZ and RPE loss on OCT was established using DL. A reliable quantitative structure/function association provides the base for developing functional endpoints in clinical care and approval of novel therapeutics for GA.

Для цитирования: Birner Klaudia, Mai Julia, Boryshchuk Daniela, Frommlet Florian, Enzendorfer Marie Louise, Schürer-Waldheim Simon, Gumpinger Markus, Vogl Wolf-Dieter, Leingang Oliver, Sacu Stefan, Schmidt-Erfurth Ursula. Exploring Trial Endpoints in Geographic Atrophy Based on Localized Functional Changes in Microperimetry and AI-Quantified OCT Biomarkers.. Investigative ophthalmology & visual science. 2026. DOI: 10.1167/iovs.67.1.22.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.