m+Medelevator.RU
← Поиск публикаций
Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver · 2020

Histological assessment of gastric pseudopyloric metaplasia: Intra- and inter-observer consistency.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rugge Massimo, Sacchi Diana, Genta Robert M, Zanco Francesca, Guzzinati Stefano, Pizzi Marco, Fassan Matteo, Di Sabatino Antonio, El-Serag Hashem

Аннотация

BACKGROUND: The histological spectrum of oxyntic mucosal atrophy (a major determinant of gastric cancer risk) includes pseudopyloric metaplasia (PPM), which histological assessment has been regarded as unreliable. PPM consistently expresses Trefoil-Factor 2 (TFF2), which is histochemically detecteble (TFF2-IHC).

AIMS: Intra- and inter-observer consistency in assessing PPM was examined using both hematoxylin & eosin (H&E) and TFF2-IHC.

MATERIALS AND METHODS: Seventy-four oxyntic biopsy samples obtained from autoimmune gastritis were considered. Two serial histological sections obtained from the paraffin-embedded tissue-samples were stained with H&E and TFF2-IHC. Three pathologists (Alpha, Beta, Gamma) independently scored PPM by both staining and the Intra- and inter-observer consistency (H&E versus TFF2-IHC) was calculated using k-statistics and/or Spearman's coefficient.

RESULTS: Based on H&E-stain versus TFF2-IHC, intra-observer consistency in PPM assessement was ranked as consistently "good" (k-values: Alpha=0.79; Beta=0.78; Gamma=0.75). Based on H&E, the overall PPM inter-observer consistency among the 3 observers was ranked as "good" (k=0.77) (the inter-observer consistency for pairs of observers was as follows: Alpha versus Beta k=0.88; Alpha versus Gamma k=0.87; Beta versus Gamma k=0.80). Based on TFF2-IHC, the overall PPM inter-observer agreement was ranked as "excellent" (k=0.91) (the inter-observer consistency for pairs of observers was as follows: Alpha versus Beta k=1; Alpha versus Gamma k=0.91; Beta versus Gamma k=0.91).

CONCLUSION: Relying on either H&E staining or TFF2-IHC, pathologists assess PPM consistently.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты