MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cid.13321

Медицинская библиотека · Clinical implant dentistry and related research · 2024

Does intra-oral scan improve the impression accuracy of full-arch implant-supported prostheses: A systematic review and meta-analysis.

Cai Zheng-Zhen, Li Xin, Wu Xin-Yu, Lai Hong-Chang, Shi Jun-Yu

СтатьяСистематический обзорМетаанализПеревод пока не подготовлен

Аннотация

OBJECTIVES

The present study aimed to systematically review the studies comparing the accuracy of intraoral scan (IOS) and conventional implant impressions (CI) in completely edentulous patients.

MATERIALS AND

METHODS

Electronic searches were performed in PubMed, Embase and Cochrane CENTRAL up to December 1, 2023. Clinical studies and in vitro studies reporting the accuracy of digital full arch impressions were included. The primary outcome is the 3-dimensional deviations between the study reference models. A risk of bias assessment was performed for clinical studies. A stratified meta-analysis and a single-armed meta-analysis were conducted.

RESULTS

A total of 49 studies were included, with 8 clinical studies and 41 in vitro studies. For comparison between IOS and conventional impressions, studies were categorized into two groups based on the different measurement methods employed: RMS and CMM. In studies using RMS, the result favored the IOS in the unparalleled situation with the mean difference of -99.29 μm (95% CI: [-141.38, -57.19], I2 = 81%), while the result was opposite with the mean difference of 13.62 μm (95% CI: [10.97, 16.28], I2 = 26%) when implants were paralleled. For different brands of IOS, the accuracy ranged from 76.11 μm (95% CI: [42.36, 109.86]) to 158.63 μm (95% CI: [-14.68, 331.93]).

CONCLUSIONS

Accuracy of intraoral scan is clinically acceptable in edentulous arches, especially for unparalleled implants. More clinical studies are needed to verify the present finding.

Для цитирования: Cai Zheng-Zhen, Li Xin, Wu Xin-Yu, Lai Hong-Chang, Shi Jun-Yu. Does intra-oral scan improve the impression accuracy of full-arch implant-supported prostheses: A systematic review and meta-analysis.. Clinical implant dentistry and related research. 2024. DOI: 10.1111/cid.13321.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.