MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3290/j.ijcd.b5117247

Медицинская библиотека · International journal of computerized dentistry · 2025

Clinical assessment of maxillary screw-retained implant prostheses fabricated from digital versus conventional full-arch implant impressions. A randomized controlled clinical trial.

Elawady Dina Mohamed, Denewar Mohamed, Alqutaibi Ahmed Yaseen, Ibrahim Wafaa Ibrahim

СтатьяРандомизированное исследованиеСравнительное исследованиеПеревод пока не подготовлен

Аннотация

AIM: The objective of the present study was to evaluate the peri-implant marginal bone loss (MBL) and prosthodontic complications of maxillary screw-retained implant prostheses fabricated from digital versus conventional full-arch implant impressions.

MATERIALS AND

METHODS

Twenty-eight participants with edentulous maxillary arches were randomly selected and enrolled in two equal groups: Group I (conventional impression group, CIG); Group II (digital impression group, DIG). All patients were rehabilitated with a maxillary screw-retained implant prosthesis retained by six implants. Peri-implant MBL and prosthodontic complications were recorded at 6, 12, and 24 months. Data were collected and statistically analyzed.

RESULTS

Regarding the effect of time, there was a statistically significant increase in MBL at the 6-, 12-, and 24-month follow-ups (P 0.001). Regarding the effect of groups, there was no statistically significant difference in MBL between CIG and DIG at 6, 12, and 24 months, where P = 0.083, 0.087, and 0.133, respectively. Prosthetic complications were recorded 19 times in CIG and 12 times in DIG, with no significant difference between the groups (P = 0.303).

CONCLUSION

Digital full-arch implant impression is a reliable impression technique and may represent an alternative to conventional implant impression technique in the fabrication of maxillary screw-retained implant prostheses.

Для цитирования: Elawady Dina Mohamed, Denewar Mohamed, Alqutaibi Ahmed Yaseen, Ibrahim Wafaa Ibrahim. Clinical assessment of maxillary screw-retained implant prostheses fabricated from digital versus conventional full-arch implant impressions. A randomized controlled clinical trial.. International journal of computerized dentistry. 2025. DOI: 10.3290/j.ijcd.b5117247.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.