Radial energy-quantile estimation for geometry-aware local wavenumber mapping in harmonic shear-wave elastography.

Gomez-Ramirez Sara, Flores Barrera Gilmer A, Castaneda Benjamin

СтатьяПеревод пока не подготовлен

Аннотация

Objective.Local wavenumber estimation in harmonic shear-wave elastography is strongly influenced by wavefield geometry. We introduce the radial energy-quantile (REQ) estimator, a local spectral method designed to estimate wavenumber across directional, intermediate, and projected diffuse wavefield regimes.Approach.REQ defines the local wavenumber as the radial spatial frequency at which the cumulative angularly averaged power spectrum reaches a prescribed quantile, denoted by. The value ofis selecteda priorifrom discrete-consistent theoretical models that account for finite windowing, Fourier sampling, and radial binning. The dependence ofon wavefield geometry was characterized using aperture-controlled simulations. REQ was subsequently evaluated using full-wave k-Wave simulations, tissue-mimicking gelatin phantoms with independent mechanical reference measurements, andex vivobovine liver and kidney experiments. REQ was benchmarked against the angular integral autocorrelation (AIA) estimator in the k-Wave simulations and in the inclusion phantom.Main results.The required quantile increased as the angular support of the wavefield broadened from predominantly directional propagation toward the projected diffuse 3D regime. In k-Wave simulations, REQ produced lower inclusion-region absolute percentage error than the AIA estimator in all four evaluated wavefield classes, with maximum errors of 5.97% and 28.27%, respectively. The mean estimator runtime wass for REQ, compared withs for the comparator. In phantom experiments, REQ preserved the expected contrast between the soft and stiff regions under both excitation configurations. In the inclusion phantom, REQ also showed lower spatial variability, smaller distances to the mechanical reference bands, and better contrast recovery than AIA under both excitation configurations. In theex vivoexperiments, REQ recovered tissue-background differences and frequency-dependent responses in both liver and kidney.Significance.REQ provides a physically interpretable and computationally efficient framework for geometry-aware local wavenumber estimation across a broad range of harmonic wavefield conditions. These results support further development toward adaptive local quantile selection, fully three-dimensional implementations, and broaderin vivovalidation.

Для цитирования: Gomez-Ramirez Sara, Flores Barrera Gilmer A, Castaneda Benjamin. Radial energy-quantile estimation for geometry-aware local wavenumber mapping in harmonic shear-wave elastography.. Physics in medicine and biology. 2026. DOI: 10.1088/1361-6560/ae99a8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.