A comparative analysis of periapical radiography and cone-beam computerized tomography for the evaluation of endodontic obturation length.

Cheng Li, Zhang Ru, Yu Xuan, Tian Yuanyuan, Wang Hu, Zheng Guangning, Hu Tao

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aim of this study was to determine the consistency and inconsistency between the periapical radiography (PR) and cone-beam computerized tomography (CBCT) in evaluating the length of root canal obturations (RCOs) in vivo.

STUDY

DESIGN

Thirty-six maxillary and mandibular first and second molars yielding 109 obturated root canals with available PR and CBCT images were analyzed. The inclusion criterion was that the RCO extended 0-2 mm short of the radiographic apex on PR images. Teeth having root canal calcification, apical resorption, or poor quality PR/CBCT images were excluded. Agreement and disagreement between the 2 imaging modalities for obturation length were analyzed using the χ(2) test.

RESULTS

A total of 30.3% of the RCOs evaluated by PR as having adequate length were diagnosed by CBCT to have inadequate length. Among these, 13.8% were overextended and 16.5% underextended as diagnosed by CBCT. When the distance from the filling tip to the radiographic apex was 0.5 to 1 mm on the PR image, the discordance rate was the lowest (11.1%) in all evaluated distance groups, significantly lower than with distances of 0-0.5 mm and 1.5-2 mm (P < .01). When RCOs were diagnosed as terminating at the facial/lingual side, overextension was the main evaluation result by CBCT in the disagreement evaluation with PR and significantly more frequent than those at the mesial/distal/central side (P < .01).

CONCLUSIONS

CBCT evaluated 30.3% of the RCOs with radiographically adequate length as inadequate. When the RCOs radiographically terminated 0.5-1 mm short of the apex, the evaluation rated adequate for obturation length was comparatively reliable.

Для цитирования: Cheng Li, Zhang Ru, Yu Xuan, Tian Yuanyuan, Wang Hu, Zheng Guangning, Hu Tao. A comparative analysis of periapical radiography and cone-beam computerized tomography for the evaluation of endodontic obturation length.. Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics. 2011. DOI: 10.1016/j.tripleo.2011.04.025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.