DOI 10.3928/1081597x-20260504-03

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026

Severity-Graded Repeatability of AS-OCT Including Epithelial and Stromal Metrics in Patients With Keratoconus Versus Healthy Individuals.

Khoramnia Ramin, Naujokaitis Tadas, Friedrich Maximilian, Son Hyeck-Soo, Auffarth Gerd U, Augustin Victor A

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

PURPOSE: To compare the repeatability of corneal parameters measured by anterior segment optical coherence tomography (AS-OCT) in patients with keratoconus and healthy individuals.

METHODS

This monocentric cross-sectional study included 136 individuals in total: 95 patients with keratoconus and 41 healthy individuals. Three AS-OCT measurements were performed on the same day using the Anterion (Heidelberg Engineering). One eye per patient was randomly selected and repeatability coefficients (RCs) with two-sided 95% CIs were calculated for anterior and posterior keratometry, as well as corneal pachymetric, epithelial, and stromal parameters. The repeatability of measured parameters was compared between patients with keratoconus and healthy individuals and in different keratoconus severity groups using intra-subject variance.

RESULTS

The RC of maximum keratometry (Kmax) (two-sided 95% CI) was 0.33 diopters (D) (range: 0.29 to 0.39 D) in healthy eyes and 0.68 D (range: 0.62 to 0.76 D) in eyes with keratoconus. The RC of anterior Kmean was 0.19 D (range: 0.17 to 0.23 D) and 0.37 D (range: 0.33 to 0.41 D), the RC of anterior corneal astigmatism was 0.28 D (range: 0.24 to 0.33 D) and 0.43 D (range: 0.39 to 0.48 D), and the RC of minimum corneal thickness was 1.98 µm (range: 1.72 to 2.34 µm) and 2.15 µm (range: 1.96 to 2.39 µm) in healthy eyes and eyes with keratoconus, respectively. Patients with keratoconus had a lower measurement repeatability for most measured parameters, including Kmax (P < .001, Mann-Whitney U test, two-tailed) compared to the healthy individuals. Repeatability tended to worsen with increasing keratoconus severity.

CONCLUSIONS

Although the AS-OCT demonstrated a high measurement repeatability in both healthy eyes and eyes with keratoconus, the repeatability of most evaluated parameters was slightly lower in patients with keratoconus and tended to worsen with increasing keratoconus severity.

Для цитирования: Khoramnia Ramin, Naujokaitis Tadas, Friedrich Maximilian, Son Hyeck-Soo, Auffarth Gerd U, Augustin Victor A. Severity-Graded Repeatability of AS-OCT Including Epithelial and Stromal Metrics in Patients With Keratoconus Versus Healthy Individuals.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2026. DOI: 10.3928/1081597x-20260504-03.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.