OBJECTIVE

This study aims to evaluate the risk of occupational exposure to hazardous medicinal products (HMPs) when utilising robotic compounding systems for the preparation of antineoplastic sterile medications. Specifically, it assesses the levels of HMPs present on the surfaces of ready-to-use preparations and on the gloves worn by personnel involved in the compounding process.

METHODS

The study was conducted over three consecutive days during routine production with a robotic compounding system. Each day, wipe samples were collected from the surfaces of 20 HMPs preparations and from the gloves of the operator involved in the compounding process. Analyses were performed using an Ultra-High Performance Liquid Chromatography (UHPLC) system to detect and quantify 25 commonly used anticancer molecules in hospital pharmacies.

RESULTS

Throughout the study, the robot compounded 60 bags of 19 different drugs, including 5-fluorouracil, bevacizumab, carboplatin, cisplatin, cyclophosphamide, docetaxel, doxorubicin, eribulin, etoposide, gemcitabine, irinotecan, nivolumab, oxaliplatin, paclitaxel, panitumumab, pembrolizumab, pemetrexed, trastuzumab, and vinorelbine. Only negligible amounts of gemcitabine, below the quantification limit (<0.0025 ng/cm²), were detected on the surfaces of 10 out of the 60 bags and on two of the operator's gloves.

CONCLUSION

The results demonstrate that surface contamination levels of HMPs in robotic compounding are exceedingly low and, in most cases, undetectable. Occupational exposure to HMPs remains consistently below 0.1 ng/cm2, a threshold deemed safe according to various studies. These findings assure the safety of compounding personnel and other hospital staff involved in cancer treatment.

Для цитирования: Riestra Ana C, Urretavizcaya Mikel, Ferro Uriguen Alexander, Olariaga Sarasola Olatz, Iglesias Ainara, Camba Yoana, Asensio Bermejo Ainhoa, Tames Maria Jose. Monitoring of occupational exposure to hazardous medicinal products in robotic compounding.. European journal of hospital pharmacy : science and practice. 2025. DOI: 10.1136/ejhpharm-2024-004294.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.