MedElevator Войти в исследования
← Поиск публикаций

DOI 10.14245/ns.1938344.172

Медицинская библиотека · Neurospine · 2020

Novel Technique for C1-2 Interlaminar Arthrodesis Utilizing a Modified Sonntag Loop-Suture Graft With Posterior C1-2 Fixation.

Koffie Robert M, Larsen Alexandra M Giantini, Grannan Benjamin L, Hadzipasic Muhamed, Yanamadala Vijay, Beaver Laura Van, Shankar Ganesh M, Shin John H

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Conventional techniques for atlantoaxial fixation and fusion typically pass cables or wires underneath C1 lamina to secure the bone graft between the posterior elements of C1-2, which leads to complications such as cerebrospinal fluid (CSF) leak and neurological injury. With the evolution of fixation hardware, we propose a novel C1-2 fixation technique that avoids the morbidity and complications associated with sublaminar cables and wires.

METHODS

This technique entails wedging and anchoring a structural iliac crest graft between C1 and C2 for interlaminar arthrodesis and securing it using a 0-Prolene suture at the time of C1 lateral mass and C2 pars interarticularis screw fixation.

RESULTS

We identified 32 patients who underwent surgery for atlantoaxial with our technique. A 60% improvement in pain-related disability from preoperative baseline was demonstrated by Neck Disability Index (p < 0.001). There were no neurologic deficits. Complications included 2 patients CSF leaks related to presenting trauma, 1 patient with surgical site infection, and 1 patient with transient dysphagia. The rate of radiographic atlantoaxial fusion was 96.8% at 6 months, with no evidence of instrumentation failure, graft dislodgement, or graft related complications.

CONCLUSION

We demonstrate a novel technique for C1-2 arthrodesis that is a safe and effective option for atlantoaxial fusion.

Для цитирования: Koffie Robert M, Larsen Alexandra M Giantini, Grannan Benjamin L, Hadzipasic Muhamed, Yanamadala Vijay, Beaver Laura Van, Shankar Ganesh M, Shin John H. Novel Technique for C1-2 Interlaminar Arthrodesis Utilizing a Modified Sonntag Loop-Suture Graft With Posterior C1-2 Fixation.. Neurospine. 2020. DOI: 10.14245/ns.1938344.172.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.