MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3760/cma.j.issn.2095-4352.2019.11.007

Медицинская библиотека · Zhonghua wei zhong bing ji jiu yi xue · 2019

[Experimental study of cardiac function by high-resolution ultrasound in sepsis rats with cecal ligation and puncture].

Xiao Yawen, Gai Mintao, Wang Yi, Hua Xiaoli, Yu Xiangyou

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the cardiac function of cecal ligation and puncture (CLP) induced sepsis rats with high-resolution ultrasound.

METHODS

According to the method of random number table, 48 adult male Sprague-Dawley (SD) rats were randomly divided into normal control group and sepsis 6, 12, 24, 30, 48 hours groups, with 8 rats in each group. The sepsis model was produced by CLP, and the rats in the normal control group were only anesthetized and resuscitated. The general situation after modeling in each group was observed, and the left ventricular function was assessed by high-resolution echocardiography at all the time points. The abdominal aorta blood of rats was collected, and the serum levels of tumor necrosis factor-α (TNF-α), interleukin-1β (IL-1β) and MB isoenzyme of creatine kinase (CK-MB) were determined by enzyme-linked immunosorbent assay (ELISA). The myocardial tissue was harvested, and the pathological changes in myocardial tissue were observed by hematoxylin-eosin (HE) staining.

RESULTS

The rats challenged to CLP displayed symptoms of sepsis, such as depression, ruffled fur, decreased diet and activity, and the symptoms became more obvious with the extension of time. High-resolution echocardiography could clearly show the structure of left ventricle in each group and obtain satisfactory M-mode echocardiography of left ventricle. The heart rate (HR) of rats in all sepsis groups was elevated with the increase in model time as measured by high-resolution ultrasound, and it was significantly higher than that in the normal control group at 12, 24, 30 hours (bpm: 359.66±23.33, 361.35±12.85, 392.67±11.33 vs. 306.24±29.79, all P < 0.05). Stroke volume (SV) and cardiac output (CO) in sepsis rats were decreased with the increase in model time, while left ventricular ejection fraction (LVEF) and left ventricular fractional shortening (LVFS) were increased first and then decreased, and SV and LVEF in sepsis 48 hours group were significantly lower than those in the normal control group [SV (μL): 78.43±17.52 vs. 122.61±15.88, LVEF: 0.763±0.018 vs. 0.902±0.011, both P < 0.05]. Left ventricular weight (LVW) in all sepsis groups was increased to different degrees as compared with that in the normal control group, as well as the left ventricular anterior and posterior wall thickness increased in diastole and systole. Compared with the normal control group, the left ventricular posterior wall thickness was increased significantly at the end of diastolic and systolic period in the sepsis 12 hours group, and the left ventricular anterior wall thickness was also increased significantly at the end of diastolic period in the sepsis 48 hours group. The serum levels of TNF-α, IL-1β and CK-MB in sepsis rats were increased first and then decreased with the extension of model making time. The above parameters in the sepsis 48 hours group were still significantly higher than those in the normal control group [TNF-α (ng/L): 61.59±3.99 vs. 16.87±4.89, IL-1β (ng/L): 255.03±13.23 vs. 119.59±10.43, CK-MB (μg/L): 1.27±0.15 vs. 0.52±0.15, all P < 0.05]. HE staining showed that the myocardial striations of the rats in the normal control group were clear and complete, with normal morphology and orderly arrangement of cardiac cells. However in the sepsis groups, myocardial cells were swollen, ruptured and necrotic, and inflammatory cells were infiltrated, with myocardial fibers ruptured and necrosis dissolved, and the above pathological manifestations gradually increased with the extension of the model making time.

CONCLUSIONS

High-resolution ultrasound can evaluate the cardiac function of CLP induced sepsis rat model more comprehensive, and the consequence of evaluation index is consistent with the expression level of myocardial enzyme and histopathologic manifestations.

Для цитирования: Xiao Yawen, Gai Mintao, Wang Yi, Hua Xiaoli, Yu Xiangyou. [Experimental study of cardiac function by high-resolution ultrasound in sepsis rats with cecal ligation and puncture].. Zhonghua wei zhong bing ji jiu yi xue. 2019. DOI: 10.3760/cma.j.issn.2095-4352.2019.11.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.