Geometrical comparison of a dedicated flaring bridging stent compared with an all-rounder product in fenestrated endovascular aneurysm repair.

Hasemaki Natasha, Stana Jan, Stavroulakis Konstantinos, Maltezos Konstantinos, Khangholi David, Haddad Yassine, Konstantinou Nikolaos, Tsilimparis Nikolaos

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The aim of this study is to compare early target vessel (TV) outcomes, procedural efficiency, and postoperative geometrical configuration of a dedicated flaring bridging stent graft with an established balloon-expandable covered stent graft in patients undergoing FEVAR or F/BEVAR.

METHODS

This retrospective comparative cohort study included consecutive patients with FEVAR or F/BEVAR between September 2018 and February 2026. TVs treated with BeFlared were compared with TVs treated with BeGraft Peripheral. Primary endpoints were technical success and geometrical layout analysis.

RESULTS

The study cohort comprised 225 patients and 831 TVs, including 159 treated with BeFlared and 672 treated with BeGraft Peripheral. Target-vessel distribution was comparable between groups. Technical success was 99.4% for BeFlared and 97.9% for BeGraft Peripheral (P=0.33). Thirty-day TVI occurred in 0.6% versus 2.1%, respectively (P=0.33). BeFlared was associated with shorter bridging stenting time (5.1 [4.3-6.2] vs. 7.5 [4.9-9.6] minutes; P<0.001) and shorter fluoroscopy time per vessel (4.4 [4.3-4.7] vs. 7.0 [5.9-8.6] minutes; P<0.001). Geometrical analysis showed a shorter and more standardized protrusion length with BeFlared (5.27±0.47 vs. 5.75±1.05 mm; P<0.001), a higher superior flaring angle (67.2±11.3 vs. 64.8±12.8 degrees; P=0.02), and a higher flaring ratio (0.96±0.03 vs. 0.94±0.04; P<0.001).

CONCLUSIONS

In this retrospective comparison, the dedicated flaring bridging stent demonstrated comparable technical success and early TV outcomes to BeGraft Peripheral, while reducing bridging stenting and fluoroscopy time per vessel. Overall flaring geometry was broadly similar, with BeFlared showing more standardized protrusion length. Longer-term follow-up is required to determine whether these procedural and geometrical advantages translate into improved durability.

Для цитирования: Hasemaki Natasha, Stana Jan, Stavroulakis Konstantinos, Maltezos Konstantinos, Khangholi David, Haddad Yassine, Konstantinou Nikolaos, Tsilimparis Nikolaos. Geometrical comparison of a dedicated flaring bridging stent compared with an all-rounder product in fenestrated endovascular aneurysm repair.. The Journal of cardiovascular surgery. 2026. DOI: 10.23736/s0021-9509.26.13738-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.