MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cca.2014.11.011

Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2014

Rapid and sensitive detection of CALR exon 9 mutations using high-resolution melting analysis.

Lim Ken-Hong, Lin Huan-Chau, Chen Caleb Gon-Shen, Wang Wei-Ting, Chang Yu-Cheng, Chiang Yi-Hao, Lin Ching-Sung, Su Nai-Wen, Su Ying-Wen, Lin Johnson, Chang Yi-Fang, Chang Ming-Chih, Hsieh Ruey-Kuen, Kuo Yuan-Yeh, Chou Wen-Chien

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Somatic CALR exon 9 mutations have recently been identified in patients with JAK2/MPL-unmutated myeloproliferative neoplasm, and have become an important clonal marker for the diagnosis of essential thrombocythemia (ET) and primary myelofibrosis. In the present study, we sought to use high-resolution melting analysis (HRMA) as a screening method for the detection of CALR mutations.

METHODS

32 JAK2/MPL-unmutated ET patients were retrospectively enrolled and 8 healthy adults were used as wild-type control. CALR exon 9 mutation was independently screened by HRMA with the CFX Connect real-time system and Sanger sequencing. TA-cloning was used to detect CALR exon 9 mutations in patients suspected to have low mutant allele burden.

RESULTS

The maximal sensitivity of HRMA in identifying both CALR type 1 and type 2 mutants from patients' genomic DNA was 2.5%. Twenty-two samples were found to have distinct melting curves from wild-type. The presence of CALR mutations in 16 of these 22 samples was confirmed by Sanger sequencing, while the other 6 samples were wild-type by sequencing. After TA-cloning, CALR mutations were detected in 5 of 6 patients from 1 (6%) of 16 clones to 1 (2%) of 50 clones. Therefore, HRMA identified CALR mutations in 21 (65.6%) of 32 ET patients compared to 16 (50%) patients by Sanger sequencing, with a false positive rate of 3% and no false negative.

CONCLUSION

The HRMA developed in our system is a rapid and sensitive technique for the detection of CALR exon 9 mutations.

Для цитирования: Lim Ken-Hong, Lin Huan-Chau, Chen Caleb Gon-Shen, Wang Wei-Ting, Chang Yu-Cheng, Chiang Yi-Hao, Lin Ching-Sung, Su Nai-Wen, Su Ying-Wen, Lin Johnson, Chang Yi-Fang, Chang Ming-Chih, Hsieh Ruey-Kuen, Kuo Yuan-Yeh, Chou Wen-Chien. Rapid and sensitive detection of CALR exon 9 mutations using high-resolution melting analysis.. Clinica chimica acta; international journal of clinical chemistry. 2014. DOI: 10.1016/j.cca.2014.11.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.