MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ahj.2006.05.031

Медицинская библиотека · American heart journal · 2006

A randomized multicenter clinical study to evaluate the safety and efficacy of the TandemHeart percutaneous ventricular assist device versus conventional therapy with intraaortic balloon pumping for treatment of cardiogenic shock.

Burkhoff Daniel, Cohen Howard, Brunckhorst Corinna, O'Neill William W, TandemHeart Investigators Group

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIM: Despite major advances in the treatment of heart failure, cardiogenic shock (CGS) remains associated with substantial mortality. Recent data suggest that the TandemHeart percutaneous ventricular assist device (pVAD) may be useful in the management of CGS. The aim of this prospective randomized study was to test the hypothesis that the TandemHeart (pVAD) provides superior hemodynamic support compared with intraaortic balloon pumping (IABP).

METHODS

Forty-two patients from 12 centers presenting within 24 hours of developing CGS were included in the study and treated in an initial roll-in phase (n = 9) or randomized to treatment with IABP (n = 14) or TandemHeart pVAD (n = 19). Thirty patients (71%) had persistent CGS despite having an IABP in place at the time of study enrollment.

RESULTS

Cardiogenic shock was due to myocardial infarction in 70% of the patients and decompensated heart failure in most of the remaining patients. The mean duration of support was 2.5 days. Compared with IABP, the TandemHeart pVAD achieved significantly greater increases in cardiac index and mean arterial blood pressure and significantly greater decreases in pulmonary capillary wedge pressure. Overall 30-day survival and severe adverse events were not significantly different between the 2 groups.

CONCLUSION

In patients presenting within 24 hours of the development of CGS, TandemHeart significantly improves hemodynamic parameters, even in patients failing IABP. Larger-scale studies are required to assess the influence of improved hemodynamics on survival.

Для цитирования: Burkhoff Daniel, Cohen Howard, Brunckhorst Corinna, O'Neill William W, TandemHeart Investigators Group. A randomized multicenter clinical study to evaluate the safety and efficacy of the TandemHeart percutaneous ventricular assist device versus conventional therapy with intraaortic balloon pumping for treatment of cardiogenic shock.. American heart journal. 2006. DOI: 10.1016/j.ahj.2006.05.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.